期刊文献+

锁定接骨板与人工肱骨头置换治疗肱骨近端复杂骨折的临床疗效比较 被引量:6

下载PDF
导出
摘要 背景:肱骨近端复杂骨折的治疗采用接骨板还是人工肱骨头置换更适宜存在争议。目的:比较锁定接骨板与人工肱骨头置换治疗肱骨近端复杂骨折的临床效果。方法:58例肱骨近端骨折患者,男27例,女31例;年龄42~84岁,平均62.8岁。分别应用肱骨近端锁定接骨板(n=28)和人工肱骨头置换(n=30),采用Neer评分,比较两种治疗方法在术后8个月和16个月的关节功能的差异。结果:全部58例患者获得8~16个月随访,术后第8个月两种治疗方法的Neer评分无明显差异(P>0.05),但术后第16个月人工肱骨头置换患者的Neer评分各项指标均显著高于应用锁定接骨板的患者(P<0.05)。结论:人工肱骨头置换治疗肱骨近端复杂骨折远期疗效优于锁定接骨板。
出处 《中国骨与关节外科》 2012年第5期442-444,共3页 Chinese Journal of Bone and Joint Surgery
  • 相关文献

参考文献7

  • 1Naranja R J, Iannotti JR. Displaced three- and four-part prox- imal humors fractures: evaluation and management. J Am Aced Orthop Surg, 2000, 8(6): 373.
  • 2徐宏亮,吴建跃,谢士成.人工肱骨头置换术治疗肱骨近端复杂骨折疗效观察[J].山东医药,2011,51(10):51-52. 被引量:6
  • 3常山,刘战立,严小虎,余鹏,昝安全,林炎水.肱骨近端复杂骨折的治疗策略[J].实用骨科杂志,2009,15(1):23-26. 被引量:19
  • 4荣闻威.骨折.北京:秋水潭医院出版社,2004.
  • 5吴晓明,工秋根.肱骨近端骨折手术治疗-解剖学重建或人工肩关节置换.闸际骨科学杂志,2011,32(4):216-218.
  • 6Qian QR, Wu HS, Zhou WJ, et al. Proximalhumeral frac- ture treated with arthroplasty. Chin J Traumato, 2005, 8(5): 283-288.
  • 7Schliemann B, Siemoniet J, Theisen CH, et al. Complex fractures of the proximal humerus in the elderly--outcome and complications after locking plate fixation. Musculoskel- et Surg, 2012, 96 Suppl 1:$3-11.

二级参考文献11

  • 1王满宜.肩关节外科领域的发展与现状[J].中华创伤骨科杂志,2005,7(9):801-802. 被引量:20
  • 2屠重棋,杨志明,李志铭.肱骨近端三部和四部分骨折的外科治疗[J].中华创伤杂志,1997,13(1):27-28. 被引量:41
  • 3Neer CS Ⅱ . Displaced proximal humeral fractures. part Ⅰ . classification and evaluation[J]. J Bone Joint Surg (Am), 1970,52 (6) : 1077-1089.
  • 4Neer CS Ⅱ . Displaced proximal humeral fractures. part Ⅱ. treatment of three-part and four-part displacement[J]. J Bone Joint Surg(Am),1970,52(6) : 1090-1103.
  • 5Braman JP,Flatow EL. How to transition to percutaneous pinning for proximal humerus Fractures[J]. Tech Shoulder Elbow Surg,2005,6(3):171-177.
  • 6Fankhauser F,Boldin C,Schippinger G,et al. A new locking plate for unstable fracture of the proximal humerus[J]. Clin Orthop ,2005, (430) : 176-181.
  • 7Kollig E, Kutscha-Lissberg F, Roetman B, et al. Primary hemiarthroplasty after complex fracture of the humeral head functional late results [J]. Zentralbl Chir, 2003,128(2) : 125-130.
  • 8Muckter H,Herzog L,Becker M,et al. Angle and ro- tation-stable internal fixation of proximal humerus fractures with the humerus fixator plate. Early clinical experience with a newly developed implant[J]. Chirurg,2001,72(11);1327-1335.
  • 9Plecko M, Krausl A. Internal fixation of proximal humerus fractures using the locking proximal humerus plate[J]. Oper Orthop Traumatol, 2005,17 (1) :25-50.
  • 10Lungershausen W,Bach O, Lorenz CO. Locking plate osteoynthesis for fractures of the proximal humerus[J]. Zentralbl Chir, 2003,128 (1) : 28- 33.

共引文献23

同被引文献38

引证文献6

二级引证文献38

相关作者