摘要 合成了电子转移介体锇联吡啶Os(bpy)3,采用催化伏安法研究了Os(bpy)3在ITO电极上的电化学行为,并对Os(bpy)3在葡萄糖-葡萄糖氧化酶体系中的催化反应动力学常数进行了测定。Os(bpy)3的均相反应速率常数KS为2.07×10-2cm/s,催化反应中一级反应速率常Kf为1.05×10-3s-1,二级反应速率常数Kmed为1.57×104L/(mol.s)。并采用催化伏安法测定Os(bpy)3的检出限为为0.016μmol/L。因此,Os(bpy)3作为电化学标记物,能够用于生物传感器的构建。 An electron transfer mediator osmium bipyridine was synthesized. The electrochemical behaviors of osmi- um bipyridine at ITO electrode were studied and the catalytic reaction kinetics of it in system of glucose/glucose ox- idase was measured. The homogeneous reaction rate constant (Ks ) is 2.07 ×10^-2cm/s, and the first- order reac- tion rate constant (Kf) and second -order reaction rate constant (Kmed) in catalyzed reaction are 1.05 × 10^-3s-1 and 1.57× 10^4 L/( mol. s), respectively. The detection limited is 0. 016 μmol/L. Therefore, as an electrochemical label, osmium bipyridine can be used to construct biosensor for the catalyzed signal amplification.
作者 邹蕊
出处 《延安大学学报(自然科学版)》 2012年第4期41-45,共5页 Journal of Yan'an University:Natural Science Edition
基金 宁夏师范学院科研项目(编号:QN2011008)
关键词 锇联吡啶 催化反应动力学 ITO电极 Osmium Bipyridine catalytic reaction kinetics ITO electrode
  • 相关文献

参考文献21

  • 1Lira T K, Ohta H. Microfabricated on - chip - type electro- chemical flow immunoassay system for the detection of hista- mine released in whole blood samples [ J ]. Anal Chem, 2003,75:3316 - 3321.
  • 2Dai J H, Baker G L. Use of porous membranes modified with polyelectrolyte multilayers as substrates for protein arrays with low nonspecific adsorption [ J ]. Anal Chem, 2006,78 : 135 - 140.
  • 3Padeste C, Grubelnik A, Tiefenauer L. Ferrocene - avidin conjugates for bioelectrochemical apphcations [ J ]. Biosen- sors and Bioelectronics,2000,15:431 -438.
  • 4Qiu j D, Deng M Q. Ferrocene - modified multiwalled carbon nanotubes as building block for construction of reagentless en- zyme- based biosensor [ J]. Sensors and Actuators B,2008, 135:181 - 187.
  • 5Zheng D, Wang N. Reusable electrochemical sensing platform for highly sensitive detection of small molecules based on structure - switching signaling aptamers [ J ]. Analytica Chim- ica Acta,2004,508:225 - 231.
  • 6Xu C, Cai H, He P G. Electrochemical detection of sequence -specific dna using a DNA probe labeled with aminoferro- cene and chitosan modified electrode immobilized with ssDNA [ J ]. Analyst,2001,126:62 - 65.
  • 7Yang M L,Liu C Z, et al. Study on the electrochemilumines- cence behavior of ABEl and its application iin dna hybridiza- tion analysis [ J ]. Analyst,2002,127 : 1267 - 1271.
  • 8Morris N A, Cardosi M F. An electrochemical capillary fill de- vice for the analysis of glucose incorporating glucose oxidase and ruthenium (iii) hexamine as mediator [ J ]. Electroanaly- sis, 1992,4 : 1 - 9.
  • 9Ohara T J, Rajagopalan R. Glucose electrodes based on cross - linked bis(2,2"- bipyridine) chloroosmium( +/2 + ) com- plexed poly ( 1 - vinylimidazole ) films [ J ]. Anal Chem, 1993,65:3512 - 3517.
  • 10Fraser D M,Zakeeruddin S M. Towards mediator design:II. Optimization of mediator global charge for the mediation of glucose oxidase of Aspergillus niger [ J ]. Electroanal Chem, 1993,359 : 125 - 139.

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部