期刊文献+

环介导等温扩增技术及其在病原微生物检测中的应用 被引量:3

Loop-mediated isothermal amplification technology and its application in pathogenic microorganism detection
下载PDF
导出
摘要 环介导等温扩增(LAMP)技术是近年发展起来的一项新的快速核酸恒温扩增技术,具有高效、快速、特异、易检测、易操作等特点,自面世以来被科学家认为是能替代常规PCR的一项扩增技术,非常适用于现场检测和基层检测。本文就LAMP技术的原理、特点、进展及其在病原微生物检测中的应用进行了简要的概述。 Loop-mediated isothermal amplification(LAMP) technology is a novel nucleic acid isothermal amplification technology developed in recent years.Because of its high effiency,rapidity,specificity,and simplicity,scientists believe it will be a routine amplification technology replacing the conventional PCR method.This paper briefly reviews the principle of the technology,techinical characteristics,progress,and its application in pathogenic microorganism detection.
出处 《基础医学与临床》 CSCD 北大核心 2013年第1期19-23,共5页 Basic and Clinical Medicine
关键词 环介导等温扩增 检测 病原体 loop-mediated isothermal amplification detection pathogenic microorganism
  • 相关文献

参考文献29

  • 1Notomi T,Okayama H,Masubuchi H. Loop-mediated isothermal amplification of DNA[J].Nucleic Acids Research,2000,(12):e63.doi:10.1093/nar/28.12.e63.
  • 2Yoshida A,Nagashima S,Ansai T. Loop-mediated isothermal amplification method for rapid detection of the periodontopathic bacteria porphyromonas gingivalis,tra-nerella for sythia,and treponema denticola[J].Journal of Clinical Microbiology,2005.2418-2424.
  • 3Lee MS,Lin YC,Lai GH. One-step reverse-transcription loop-mediated isothermal amplification for detection of infectious bursal disease virus[J].Canadian Journal of veterinary research-revue canadienne de recherche vet,2011.122-127.
  • 4Qiao J,Meng Q,Cai X. Rapid detection of Betacoronavirus 1 from clinical fecal specimens by a novel reverse transcription loop-mediated isothermal amplification assay[J].Journal of Veterinary Diagnostic Investigation,2012.174-177.
  • 5Nemoto M,Yamanaka T,Bannai H. Development of a reverse transcription loop-mediated isothermal amplification assay for H7N7 equine influenza virus[J].Journal of Veterinary Medical Science,2012.929-931.
  • 6Kelly AC,Donna LR,Michele OS. Rapid detection of HIV-1 by reverse-transcription loop-mediated isothermal amplification (RT-LAMP)[J].Virological Ethods,2008.264-270.
  • 7Dugan L,Bearinger J,Hinckley A. Detection of Bacillus anthracis from spores and cells by loop-mediated isothermal amplification without sample preparation[J].Journal of Microbiological Methods,2012.280-284.
  • 8Sappat A,Jaroenram W,Puthawibool T. Detection of shrimp Taura syndrome virus by loop-mediated isothermal amplification using a designed portable multi-channel turbidimeter[J].Journal of Virological Methods,2011.141-148.
  • 9Hataoka Y,Zhang L,Mori Y. Analysis of Specific Gene by Integration of Isothermal Amplification and Electrophoresis on Polyfmethyl methacrylate Microchips[J].Analytical Chemistry,2004.3689-3693.
  • 10Maruyama F,Kenzaka T,YamaguchiN. Detection of bacteria carrying the stX2 gene by in situ loop-mediated isothermal amplification[J].Applied and Environmental Microbiology,2003,(8):5023-5028.doi:10.1128/AEM.69.8.5023-5028.2003.

二级参考文献27

  • 1陈敏,周陶友,陈文昭,尹维佳,舒明蓉,吕晓菊.耐甲氧西林金黄色葡萄球菌感染的临床和耐药性[J].中华医院感染学杂志,2004,14(2):223-225. 被引量:102
  • 2温杰,刘毅.16S rRNA基因RFLP用于不同科细菌区分[J].大连医科大学学报,2005,27(3):237-239. 被引量:6
  • 3Niederhauser C, Hofelein C, Wegmuller B, et al. Reliability of PCR decontamination systems[J]. PCR Methods Appl, 1994,4 (2): 117-123.
  • 4Notomi T, Okayama H, Masubuchi H,et al. Loop mediated iso thermal ampllfication of DNA[J]. Nucl Acids Res, 2000,28 : E63.
  • 5Bialasiewicz S, Whi|ey DM, Nissen MD, et al. Impact of competitive inhibition and sequence variation upon the sensitivity of malaria PCR[J]. Clin Microbiol,2007,45(5) : 1621-1623.
  • 6Cox-Singh J, Davis TM, Lee KS, et al. Plasmodium knowlesi malaria in humans is widely distributed and potentially life threatening [J]. Clin Infect Dis,2008,46(2) : 165-171.
  • 7Erdman LK, Kain KC. Molecular diagnostic and surveillance tools for global malaria control [J]. Travel Med Infect Dis, 2008,6 (1) : 82-99.
  • 8Boehme CC, Nabeta P, Henostroza G, et al. Operational feasibility of using loop-mediated isothermal amplification for diagnosis of pulmonary tuberculosis in microscopy centers of developing countries [ J ]. Clin Microbiol, 2007,45 (6) : 1936-1940.
  • 9Curtis KA, Rudolph DL, Owen SM. Rapid detection of HIV-1 by reverse-transcription, loop-mediated isothermal amplification (RT- LAMP) [ J 1. Virol Methods, 2008,151 (2) : 264-270.
  • 10Elsayed S, Plewes K, Church D, et al. Use of molecular beacon probes for real-time PCR detection of Plasmodiumfalciparum and other Plasmodium species in peripheral blood specimens [J]. Clin Microbiol, 2006,44 (2) : 622-624.

共引文献37

同被引文献59

  • 1肖敏,易勇,毛旭虎,罗萍,聂棱,贾莉萍,魏平,王惠,敬华,邹全明.免疫磁分离及免疫比浊分析对福氏志贺菌的自动快速定量检测[J].免疫学杂志,2009,25(3):341-345. 被引量:8
  • 2何英,陆学东.液相芯片技术及其临床应用[J].国际检验医学杂志,2006,27(12):1107-1108. 被引量:14
  • 3Fedorko DP, Williams EC. Use of eycloserine-cefoxitin-fructose agar and L-proline-aminopeptidase(PRO Discs) in the rapid iden- tification of Clostridium difficile [ J ]. J Clin Microbiol, 1997,35 (5) : 1258-1259.
  • 4Clark AG, MeLaughlin J. Simple color tests based on an alanyl peptidase reaction which differentiate Listeria monoeytogenes from other Listeria species [J]. J Clin Microbiol, 1997, 35 (8) : 2155-2156.
  • 5Escamilla Gomez V, Campuzano S, Pedrero M, et al. Immunosen sor for the determination of Staphylococcus aureus using a tyrosi- nase-mercaptopropionic acid modified electrode as an amperomet- tic transducer[J]. Anal Bioanal Chem, 2008,391 (3) : 837-845.
  • 6Guo X,Lin CS,Chen SH,et al. A piezoelectric immunosensor for specific capture and enrichment of viable pathogens by quartz crystal microbalance sensor, followed by detection with antibody functionalized gold nanoparticles[J]. Biosens Bioelectron,2012,38 (1) ,177-183.
  • 7Ohk SH,Bhunia AK. Multiplex fiber optic biosensor for detection of Listeria monocytogenes,Escheriehia coli O157:H7 and Salmo- nella enterica from ready-to-eat meat samples[J]. Food Microbiol, 2013,33(2) :166-171.
  • 8Yamazaki W. Sensitive and rapid detection of cholera toxin-produ- cing Vibrio cholerae using loop-mediated isothermal amplification [J]. Methods Mol Biol,2011,739(2) :13 -22.
  • 9Kim DW, Kilgore PE, Kim EJ, et al. The enhanced pneumococcal LAMP assay:a clinical tool for the diagnosis of meningitis due to Streptococcus pneumoniae[J]. PLoS One, 2012,7(8) : e42954.
  • 10Dugan L,Bearinger J, Hinckley A, et al. Detection of Bacillus an- thracis from spores and cells by loop-mediated isothermal amplifi- cation without sample preparation[J]. J Microbiol Methods, 2012, 90(3) :280 -284.

引证文献3

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部