为了探测激光诱导击穿光谱(LIBS)的信号,设计了CCD同步光谱测量系统。该系统采用高灵敏度的SonyILX554B线阵CCD作为光谱探测器,运用一种新的驱动方法,可灵活控制CCD的触发延迟时间和光积分时间,从而最大限度地滤除LIBS背景辐射的干扰,得到最佳的原子辐射信号,提高LIBS检测的灵敏度。通过测量各种样品的LIBS信号在不同延迟时间和积分时间时的谱线图,证实其在LIBS宽谱、快速测量中的有效性,为开发低成本LIBS测量仪提供了技术依据。
A CCD pulsed signal acquisition system for the spectral measurements in laser-induced breakdown spectroscopy (LIBS) is designed. We adopt a highly sensitive Sony ILX554B linear CCD as detector, and exploit a novel CCD driving method that can freely adjust the delay time relative to the laser pulse and the integration time of the photosensitive units in the CCD. By optimizing the delay time and the integration time, it can reduce the interference of the background emissions significantly and improve the sensitivity of LIBS. The LIBS signals of several kinds of samples under different delay times and integration time are measured, and it is shown that the system has a good performance in rapid analysis of LIBS, providing technical support to develop an inexpensive LIBS instrument.
出处
《激光与光电子学进展》
CSCD
北大核心
2013年第1期196-202,共7页
Laser & Optoelectronics Progress
基金
国家重大科学研究计划(2012CB921900)
国家基础科学人才培养基金(J0730313
J0630320)资助课题