期刊文献+

热泵热水器变工况性能的无量纲对比态分析法

Dimensionless Correspondence Analysis Method for the Performance of Heat Pump Water Heater under Variable Operating Conditions
原文传递
导出
摘要 本文介绍一种热泵热水器性能的无量纲对比态分析法,该方法采用不同工况的热泵热水器性能参数与标准设计工况的参数对比的无量纲参数来描述实际工况性能。分别导出了理论和实际的描述热泵热水器变工况性能的无量纲表达式,给出了环境气温从-5~40℃,进水温度从5~30℃的无量纲性能曲线,以及两种型号的实验机的结霜温度区的实验结果无量纲对比性能。研究发现,热泵热水器的对比热水流量m_w是体现变工况性能的极为敏感和重要的参数,只有用m_w和COP相结合,才能全面反映热泵性能。 A dimensionless correspondence analysis method is proposed for the performance analysis of heat pump water heater(HPWH).The actual performances of HPWH under any operating conditions can be described by using the dimensionless parameters,which are defined as the performances of HPWH under variable operating conditions corresponding to the performances under the standard operating conditions.The expressions of the theoretical and practical dimensionless parameters are derived to describe performances of HPWH under variable operating conditions.The dimensionless performance curves of HPWH are given at ambient temperature - 5℃to 40°C and inlet-water temperature 5℃to 30℃.The dimensionless performances of experimental results of two prototypes are given at the frost temperature range.The results reveal that the corresponding hot water flow m_w is an important and sensitive parameter to reflect the performance of HPWH under variable conditions.Thus,it can fully show the performance of HPWH by combining m_w and COP.
出处 《工程热物理学报》 EI CAS CSCD 北大核心 2013年第1期9-13,共5页 Journal of Engineering Thermophysics
基金 国家自然科学基金资助项目(No.51076147)
关键词 热泵热水器 无量纲分析法 热泵效率 heat pump water heater dimensionless analysis method efficiency of heat pump
  • 相关文献

参考文献2

二级参考文献5

  • 1李妩,陶文铨,康海军,李惠珍,辛荣昌.整体式翅片管换热器传热和阻力性能的试验研究[J].机械工程学报,1997,33(1):81-86. 被引量:73
  • 2彦启森,徐邦裕.空气调节用制冷技术[M].第2版.北京:中国建筑工业出版社,1999.
  • 3WANG H, TOUBER S. Distributed and non-steadystate modeling of an air cooler[J]. Int J Refrfg, 1991,14(2): 98-111.
  • 4SHAH M M. A general correlation for heat transfer during film condensation inside pipes[J]. Int J Heat Mass Transfer, 1979, 22(4) : 547-556.
  • 5G L Morrison, T Anderson, M. Behnia. Seasonal,performance rating of heat pump water heaters[J].Solar Energy ,2004, 76: 147-52.