摘要 对DN75×75和DN75×50两种PVC三通管进行了试验与数值模拟研究,结果表明主管-侧管流向的局部阻力系数ζ01和主管-直管流向的局部阻力系数ζ02随雷诺数的增大而减小,在雷诺数大于1.5×105之后基本趋于稳定;ζ01、ζ02与分流比呈二次抛物线关系,通过验证数值计算与试验结果基本吻合。在此基础上对5种常见型号的三通管进行了数值模拟,表明ζ01、ζ02随管径比的增大而减小,ζ01的变化幅度远大于ζ02的幅度,并给出了局部阻力系数随分流比变化的定量表达式;流动特征分析可知引起局部水头损失ζ01的主要原因是水流方向变化的损失和离心力造成的速度分布变化损失,而引起ζ02的主要原因是在较大分流比时水流的剪切和横向环流导致直管分岔处上侧的漩涡运动和流速梯度变化损失。 Two kinds of tee pipes DN75×75 and DN75×50 were discussed by test methods and numerical simulation. The results showed that local resistance coefficient of main branch to side branch ζ01 and main branch to straight branch ζ02 decreased with increasing Reynolds number and stabilized after the Reynolds number was greater than 1.5 × 10^5. The local resistance coefficient ζ01 and ζ02 was correlated with the flow ratio by second-order parabolic equations. The numerical simulation results were in good with the experimental data. Through those variables other five kinds of tee pipes were simulated numerically. It showed that the local resistance coefficient ζ01 and ζ02 decreased with increasing diameter ratio, and the variable extent of ζ01 was greater than ζ02. Also the expression equation of local resistance coefficient variation with the flow ratio was given simultaneously. Flow characteristics analysis showed that the main reason caused the local resistance coefficient ζ01 due to the loss of direction changes and velocity distribution caused by centrifugal force, and changes ζ02 was due to the vortex motion and velocity gradient in the straight branch caused by water shearing and transverse circulation in the large flow ratio.
出处 《农业机械学报》 EI CAS CSCD 北大核心 2013年第1期73-79,89,共8页 Transactions of the Chinese Society for Agricultural Machinery
基金 国家高技术研究发展计划(863计划)资助项目(2010AA10A302) 国家自然科学基金资助项目(50909083) 高等学校博士学科点专项科研基金资助项目(20090204110019)
关键词 PVC三通管 阻力特性 流动特征 数值模拟 PVC tee pipes Resistance characteristics Flow characteristics Numerical simulation
  • 相关文献

参考文献19

  • 1朱德兰,吴普特,王剑.滴头制造偏差对灌水均匀度及毛管造价的影响[J].排灌机械工程学报,2011,29(2):175-179. 被引量:16
  • 2Guo B Y, Tim A G L,David F F. CFD simulation of precession in sudden pipe expansion flows with low inlet swirl[J]. Applied Mathematical Modeling, 2002,26( 1 ) : 1 - 15.
  • 3GB/T50485--2009微管工程技术规范[S].2009.
  • 4Blaisdell F W, M anson P W. Energy loss at pipe junctions[ J]. ASCE Journal of Irrigation and Drainage Division, 1967,93 (3) : 59 - 78.
  • 5Samagaio A, Vlachos N S. Calculation of three-dimensional laminar flows in T-shaped junctions[ J]. Computer Methods in Applied Mechanics and Engineering, 1989, 75 ( 1 N 3) : 393 - 407.
  • 6Kuo T W, Khaligi B. Numerical study on flow distribution in T-junction and comparison with experiment [ C ]//Proceedings of ASME Internal Combustion Engine, 1995:8 -31.
  • 7Gan Guohui, Saffa B Riffat. Numerical determination of energy losses at duct junctions [ J]. Applied Energy, 2000, 67 (3) : 331 - 340.
  • 8Volker Weitbrecht, David Lehmann, Andreas Richter. Flow distribution in solar collectors with laminar flow conditions[ J ]. Solar Energy, 2003, 73(6) :433 -441.
  • 9Costa N P, Maia R, Proenca M F. Edge effects on the flow characteristics in a 90 deg tee junction[J]. ASME Journal of Fluids Engineering, 2006, 128(6) : 1 204 - 1 217.
  • 10P6rez-Garcia J, Sanmiguel-Rojas E, HernOndez-Grau J, et al. Mumerical and experimental investigations on internal comoressible flow at T-type junctions [ J ]. Experimental Thermal and Fluid Science, 2006, 31 (1) : 61 - 74.