期刊文献+

600MW机组凝泵变频运行振动分析及治理 被引量:16

Cause Analysis and Control over Vibration of Condensate Pump of 600 MW Units in Variable-frequency Operation
下载PDF
导出
摘要 某600 MW机组凝结水泵经变频改造后在变频工作区运行振动很大。通过对凝泵筒体进行理论建模计算分析,了解变频设备在变频运行范围内的特性,结合现场实际情况对凝泵先后进行了3次加固改造,有效解决了凝泵振动大的问题。 The condensate pump of 600 MW vibrates greatly in variable-frequency working area after frequen- cy conversion. By modeling of condensate pump for calculation and analysis, characteristic of variable-fre- quency equipment in scope of variable-frequency operation are learned. In combination with field practices, the condensate pump is reinforced three times, which effectively solved the problem of the great vibration of condensate pump.
出处 《浙江电力》 2013年第1期56-58,共3页 Zhejiang Electric Power
关键词 凝结水泵 变频 振动治理 condensate pump frequency conversion vibration control
  • 相关文献

参考文献1

共引文献6

同被引文献68

引证文献16

二级引证文献46