期刊文献+

基于噪声源定位测试的锚杆钻车风机系统噪声控制 被引量:2

Noise control for blower system of roof bolting jumbo based on noise source identification test
原文传递
导出
摘要 履带式锚杆钻车井下使用时存在风机系统噪声过大的问题,影响正常工作。为有效控制噪声水平,采用噪声源定位测试试验来确定主要噪声源位置及噪声源频率特性,采取有效措施降低噪声声级。试验结果表明,风机补气口为主要噪声源位置,主要噪声源是由风机运转时内部叶轮啮合在排气管道处产生的空气动力性噪声引起的。通过在补气口位置安装阻抗复合式消声器,可有效降低噪声声强级10dB(A)左右。 The blower system generates much noise when the tracked roof bolting jumbo operates in underground mines, which influences normal operation. In order to control the noise level effectively, the noise source identification test was developed to determine the location and the frequency characteristics of the noise source, so as to take effective measures to reduce the noise level. Test results showed that the air charge port of the blower was the location where primary noise generated, and which was induced by the alternate atmospheric air flows due to operating impeller engagement in the blower. After mounting a dissipation and impedance compound silencer at the air charge port of the blower, the noise intensity reduced about 10 dB(A).
作者 张晓鹍
出处 《矿山机械》 北大核心 2013年第2期20-23,共4页 Mining & Processing Equipment
基金 山西省青年科技研究基金(2011021019-2)
关键词 锚杆钻车风机系统 噪声源定位 噪声控制 补气消声器 blower system of roof bolting jumbo noise source identification noise control air compensatingsilencer