柱前衍生化高效液相色谱法测定全蝎中游离牛磺酸的含量 被引量:9

Determination of free taurine in Scorpio with precolumn derivatization
原文传递
导出
摘要 目的:建立全蝎中游离牛磺酸的含量测定方法。方法:采用50%乙醇超声提取全蝎中的游离氨基酸,异硫氰酸苯酯柱前衍生化后进行反相高效液相色谱分析。色谱柱为Agilent ZORBAX SB-C18(150mm×4.6 mm,5μm),以0.07 mol·L-1醋酸-醋酸钠缓冲液-2.5%乙腈(pH=6.5)为流动相A,乙腈-甲醇-水(40∶15∶45)为流动相B,流速1.0 mL·min-1,检测波长254 nm。结果:牛磺酸在0.008 3~0.414 8μg范围呈良好的线性关系(R2=0.999 9);平均回收率为102.1%,RSD为1.6%(n=6);全蝎中游离牛磺酸含量在0.026 9%~1.27%之间。结论:该方法灵敏度高,重复性好,结果准确可靠,可用于全蝎的质量控制。 Objective: To establish a method for determination of free taurine in Scorpio. Methods: The free taurine in Scorpio extracted with 50% alcohol by ultrasonication was precolumn derived with phenylisothocya- nate. Analysis was performed on an Agilent ZORBAX SB-C18 column (150 mm ×4.6 mm, 5 μm) with gradient e- lution of 0.07 mol· L-1 acetic acid-sodium acetate buffer-2.5% acetonitrile ( pH = 6.5 ) (A) and aeetonitrile- methanol-water (40:15 : 45 ) ( B ) at the flow rate of 1.0 mL· min - 1, and detected at 254 nm. Results: The linear- ity of the taurine derivative was good in the range of 0. 008 3 -0. 414 8 μg (R2 =0. 999 9). The average recovery was 102.1% with RSD of 1.6% (n = 6). The contents of free taurine were from 0. 026 9% to 1.27% in Scorpio. Conclusion: This method shows high sensitivity, repeatability and accuracy, and is proved to be helpful for the quality control of Scorpio effectively.
出处 《中国新药杂志》 CAS CSCD 北大核心 2013年第2期230-234,共5页 Chinese Journal of New Drugs
基金 2010-2011年度国家药品标准提高科研项目(课题编号:373) 2011年度中国药科大学大学生实践创新训练计划项目
关键词 全蝎 牛磺酸 衍生化 高效液相色谱 含量测定 Scorpio taurine derivatization HPLC determination
  • 相关文献

参考文献10

二级参考文献95

共引文献104

同被引文献132

引证文献9

二级引证文献241

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部