摘要
文章研究热控涂层GEO带电粒子辐射效应加速试验的参数确定方法。根据轨道带电粒子辐射环境的特点,以效应等效为原则,建立了利用单一能量带电粒子产生的辐射效应模拟轨道带电粒子辐射效应时的等效注量率计算方法,称之为等效能谱模拟技术;并建立了利用高注量率来提高加速试验效率的加速因子计算方法,称之为加速试验的加速因子确定技术。利用这两项技术,研究设计了防静电Kapton二次表面镜GEO电子辐射效应模拟试验的参数。
This paper proposes a technique of determining parameters in an acceleration test for the space charged particle radiation effects on thermal control coatings (TCC). Based on the characteristics of the space charged particle radiation environment, and the principle of effect equivalency, we replace the mono-energetic charged particle radiation effect for the space charged particle radiation effect to develop an equivalent dose calculation method, which is called the equivalent energy spectrum method; and also to develop a method for the calculation of the acceleration factor in testing the efficiency of acceleration with a high dose rate, which is called the acceleration factor determination method in the acceleration test. Furthermore, with these two methods, we have designed the test parameters in the simulation test of static proof Kapton second surface mirrors under the GEO electron radiation.
出处
《航天器环境工程》
2012年第5期527-531,共5页
Spacecraft Environment Engineering
基金
国家高技术研究发展计划(课题编号:2006AA04Z414)
关键词
空间带电粒子
辐射效应
等效能谱模拟
加速试验
聚酰亚胺
space charged particle
irradiation effects
equivalent spectrum simulation
acceleration test