摘要 目的探讨256层螺旋CT前瞻性心电门控技术在小儿复杂先天性心脏病(CHD)诊断中的价值。方法回顾性分析54例采用256层螺旋CT前瞻性门控技术检查的复杂CHD患儿图像,并计算有效辐射计量,患者平均年龄2岁3个月(2月~6岁4个月),所有患儿均行超声心动图检查,9例患儿行心血管造影检查,所有病例均经手术证实。结果手术证实畸形233处,256层螺旋CT敏感度为98.7%,特异度为99.9%,准确度98.5%。平均ED为(1.02土0.45)mSv。结论 256层螺旋CT前瞻性心电门控技术,有效减少辐射计量,可以清晰显示复杂CHD的病理解剖形态,特别对主动脉、肺动脉、肺静脉及侧支血管的显示具有明显优势。 Objective To study the diagnostic value of prospective-gated step-and-shoot (SAS) technique on a 256-slice Spiral CT Scanner in Complex Congenital Heart Disease. Methods Fifty-four infants (age ranged from 2months to 6 years and 4 months with mean age of 27 monthswith complicated congenital heart diseases were examined with prospective-gated step-and-shoot (SAS) technique on a 256-slice Spiral CT Scanner ,the imaging data of fifty-four infants with CCHD were retrospectively analyzed. The radiation effective dose(ED)was calculated.All of infants were examined with echocardiography(ECG), 9 of them were examined with angiocardiography. Surgical confirmation ,which was used as the reference standard, was available in all patients. Results A total of 224 cardiac deformities confirmed by operation were studied. The sensitivity, specificity, and ac curacy of 256-slice CT in detecting cardiac deformities were 98.7%, 99.9%, 98.5%. The mean ED was(1.02±0.45)mSv . Conclusion Prospective-gated step-and-shoot (SAS) technique on a 256-slice Spiral CT Scanner results in lower radiation dose. Imaging with 256-slice spiral CT is able to display the structures and malformations of infants with complex congenital heart diseases.
作者 张兴雨
出处 《当代医学》 2013年第8期58-59,共2页 Contemporary Medicine
关键词 先天性心脏病 体层摄影术 CT Congential heart disease Tomography X-ray computed
  • 相关文献

参考文献4

  • 1AAPM task group 25 of the diagnostic imaging council CT committee. The measurement reporting,and management of radiatien dose in CT[AAPM lfeport 96].Washington: American Asmciation of Physicists in Medicine, 2008 : 13.
  • 2杜靖,姜涛,周杰,吕飙,张兆琪,陈伟.320排动态容积CT对婴幼儿复杂型先天性心脏病的应用价值[J].中国医学影像技术,2011,27(6):1174-1177. 被引量:15
  • 3Donnelly LF.P.educing radiation dose.associated with pediatric CT / by decreasing unnecessary Examination[J].Am J Eoentgenol,2005,184(2)= 655-657.
  • 4Scheffel H, Alkadhi H,Leschka ,et a 1.Low-dose CT coronary angiography in the Step-arid-shoot mode=diagnosti performance[J]. Heart, 2008, 94(9)=1152-1157.

二级参考文献8

  • 1Kitagawa K,Lardo AC,Lima JA,et al.Prospective ECG-gated 320 row detector computed tomography:implications for CT angiography and perfusion imaging.Int J Cardiovasc Imaging,2009,25(2):201-208.
  • 2Wiant A,Nyberg E,Gilkeson RC.CT evaluation of congenital heart disease in adults.AJR Am J Roentgenol,2009,193(2):388-396.
  • 3Dewey M,Zimmermann E,Deissenrieder F,et al.Noninvasive coronary angiography by 320-row computed tomography with lower radiation exposure and maintained diagnostic accuracy:comparison of results with cardiac catheterization in a head-to-head pilot investigation.Circulation,2009,120(10):867-875.
  • 4Hoe J,Toh KH.First experience with 320-row multidetector CT coronary angiography scanning with prospective electrocardiogram gating to reduce radiation dose.J Cardiovasc Comput Tomogr,2009,3(4):257-261.
  • 5Klass O,Walker M,Siebach A,et al.Prospectively gated axial CT coronary angiography:comparison of image quality and effective radiation dose between 64-and 256-slice CT.Eur Radiol,2010,20(5):1124-1131.
  • 6张华山,邓建永,郭锐.MSCT诊断左上肺静脉畸形引流1例[J].中国医学影像技术,2009,25(3):430-430. 被引量:3
  • 7张建生,郭宁,王亮,徐川,覃杰,单鸿.320排动态容积CT冠状动脉成像低剂量扫描的初步探讨[J].实用医技杂志,2009,16(9):688-690. 被引量:9
  • 8彭志远,马小静,周宏,陈艳,张雪莲,陈险峰.64层螺旋CT心轴位像测评先心病主动脉骑跨程度[J].中国医学影像技术,2009,25(11):2033-2035. 被引量:7

共引文献14

同被引文献12

引证文献2

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部