AP1000核电给水流量丧失事故下避免稳压器满水措施研究 被引量:3

Study on Measures to Prevent the Pressurizer from Filling up with Water under Loss of Normal Feedwater for AP1000 NPP
下载PDF
导出
摘要 AP1000核电给水流量丧失事故下避免稳压器满水措施的研究,主要目的是掌握导致稳压器满水的主要影响因素,建立这一事故的分析方法,既考虑基于现有手段(压力容器封头排气系统)提出应对策略,又根据分析结果提出改进措施(增大非能动余热排出系统排热能力),供技术决策层参考。 The paper studies the meastures to prevent the pressurizer from filling up with water on condition of the loss of normal feedwater accident. The main aim of the study is to get knowledge about the factors causing the pressurizer filling up with water, and to creates the analysis method for the accident. Finally, the paper puts forward counter measures based on the existing reactor vessel head ventilation system, and also the design optimization to increase the capability of the passive residual heat removal system.
出处 《中国核电》 2013年第1期10-16,共7页 China Nuclear Power
关键词 给水流量丧失 事故分析 稳压器满水 措施研究 loss of normal feedwater accident analysis pressurizer filling up with water measure study