期刊文献+

基于数字图像相关法的风洞试验测量技术 被引量:3

Wind Tunnel Measurements Based on Digital Image Correlation Method
原文传递
导出
摘要 以风洞试验中的气动弹性模型表面的标记点为载体,运用数字图像相关法(DIC)对CCD摄像机高频采集的灰度图像进行处理,得到标记点在时间序列下的位移值,从而得到待测结构的振动响应。通过介绍数字图像相关法的基本原理及其在风洞试验中的应用,并将其与激光位移计进行对比试验,验证了该方法的可靠性、稳定性和优越性。 Based on mark points on the surface of bridge pneumatic model adopting the digital image correlation (DIC) method to handle the pictures captured by CCD video camera in the high frequency, the displacement values of the mark points in the time series are gotten and thus the vibration responses of the bridge are obtained. The fundamental principles of the DIC method and its application are introduced. The reliability, stability and advantages of the method are testified by the comparison of the results with those measured by the laser displacement sensor.
出处 《激光与光电子学进展》 CSCD 北大核心 2013年第5期107-113,共7页 Laser & Optoelectronics Progress
基金 国家973计划(2013CB03631) 国家自然科学基金(51278435)资助课题
关键词 测量 数字图像相关 风致振动 风洞试验 非接触 measurement digital image correlation wind-induced vibration wind tunnel test non-contact
  • 相关文献

参考文献11

二级参考文献69

共引文献136

同被引文献36

  • 1段瑞玲,李庆祥,李玉和.图像边缘检测方法研究综述[J].光学技术,2005,31(3):415-419. 被引量:376
  • 2顾国庆, 王开福, 许星. 基于数字图像相关的刚体面内微小转动测量及转动中心定位[J]. 中国激光, 2012, 39(1): 0108004.
  • 3潘兵,谢惠民.数字图像相关中基于位移场局部最小二乘拟合的全场应变测量[J].光学学报,2007,27(11):1980-1986. 被引量:113
  • 4M A Sutton, W J Wolters, W H Peters, et al.. Determination of displacements using an improved digital correlation method [J]. Image and Vision Computing, 1983, 1(3): 133-139.
  • 5S-H Tung, C-H Sui. Application of digital-image-correlation techniques in analysing cracked cylindrical pipes [J].Sadhana, 2010, 35(5): 557-567.
  • 6A b Kammers, S Daly. Self-assembled nanoparticle surface patterning for improved digital image correlation in a scanning electron microscope [J]. Experimental Mechanics, 2013, 53(8): 1333-1341,.
  • 7B S Salmons, D R Katz, M L Trawick. Correction of distortion due to thermal drift in scanning probe microscopy [ J ]. Ultramicroseopy, 2010, 110(4): 339-349.
  • 8M A Sutton, N Li, D Garcia, et al.. Scanning electron microscopy for quantitative small and large deformation :aeasurements part II: experimental validation for magnifications !rom200 to 10000 [J]. Experimental Mechanics, 2007, 47(6): 789-804.
  • 9L Larsson, M Sjodahl, F Thuvander. Microscopic 3-D displacement field measurements using digital speckle photography [J]. Opt & Lasers in Eng, 2004, 41(5): 767- 777.
  • 10G Nicoletto, T Marin, G Anzelotti, et al.. Application of high magnification digital image correlation technique to micromechanical strain analysis [J]. Strain, 2011, 47(sl): e66- e73.

引证文献3

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部