期刊文献+

羟基磷灰石涂层髋臼假体的Meta分析 被引量:1

Hydroxyapatite coated acetabular cups in primary total hip arthroplasty:a meta-analysis
原文传递
导出
摘要 [目的]系统评价生物型髋臼假体是否喷涂羟基磷灰石(hydroxyapatite,HA)在临床效果上的差异。[方法]计算机及手工检索相关的中英文文献,收集关于初次全髋关节置换术(total hip arthroplasty,THA)使用HA涂层髋臼假体和无HA涂层髋臼假体的随机对照研究(randomized controlled trial,RCT)并评价纳入研究的方法学质量。利用STATA 12.0软件进行统计分析。[结果]共纳入符合标准的相关文献7篇,纳入618个髋臼假体,Meta分析结果显示,与对照组相比,HA涂层髋臼假体在影像学松动和因松动及各种原因产生的翻修率方面无统计学差异。[结论]HA涂层没有明显改善髋臼假体的稳定性及翻修率。 [ Objective ] To evaluate the overall clinical benefit of hydroxyapatite (HA) coating in uncemented acetabular cups. [ Method ] Randomized controlled trials related to application of HA - coated acetabular cups in primary total hip arthro- plasty versus non - HA - coated cups were searched on Pubmed, Embase, ScienceDirect, OVID, Springer Link, Wiley Online Li- brary, CBM, etc. from their inception to December 2012. Some relevant journals were hand - searched as well. Two reviewers in- dependently evaluated the quality of the incluc]ed studies and extracted the data. Meta - analysis was performed by STATA 12.0 software. [ Result] Seven randomized controlled trials involving 618 acetabular cups were included. The combined results showed that there was no significant difference in the revision rate due to aseptic loosening or any cause and the radiological loosening. [ Conclusion] The use of HA - coated acetabular cups was not associated with clearly reduced overall risk of aseptic loosening and revision rate compared to non- HA- coated implants.
出处 《中国矫形外科杂志》 CAS CSCD 北大核心 2013年第10期969-975,共7页 Orthopedic Journal of China
关键词 髋假体 关节成形术 置换 羟基磷灰石 META分析 hip prosthesis, arthroplasty, replacement, hip, hydroxyapatite, meta-analysis
  • 相关文献

参考文献20

  • 1齐新生,李雪松,陈辉,李永刚.金属与羟基磷灰石微孔表面股骨植入体与骨结合强度的比较研究[J].中国矫形外科杂志,2001,8(7):678-679. 被引量:1
  • 2Bidar R, Kouyoumdjian P, Munini E,et a/. Long - term results of the abg - 1 hydroxyapatite coated total hip arthreplasty: analysis of 111 cases with a minimum follow- up of 10 years [J]. Othop Traurnatol Surg Res, 2009,8 : 579 - 587.
  • 3Chung YY, Ki SC, So KY, et al. High revision rate of hydrexyapatite - coated abg - i prosthesis [ J]. J Orthop Sci, 2009,5 : 543 - 547.
  • 4Gottliebsen M, Rahbek O, Ottosen PF, eta/. Superior 11 - year sur- vival but higher polyethylene wear of hydroxyapatite - coated mallory - head cups [J]. J Clin Exp Res Hip Pathol Ther,2012,1:35 -40.
  • 5Datir SP, Angus PD. Long term survival of an hydroxyapatite - coated threaded cup in the presence of a high pelythene wear rate [ J]. J Clin Exp Res Hip Pathol Ther,2010,3:327 -334.
  • 6Kim SY, Kim DH, Kira YG, et al. Early failure of hemispheric hydroxyapatite - coated acetabular cups [ J]. Clin Orthop, 2006,446:233 -238.
  • 7Laursen MB, Nielsen PT, SobaUe K, Bone remodelling around ha - coated acetabular cups:a dexa study with a 3 -year follow - up in a randomised trial [ J]. Int Orthop ,2007,2 : 199 - 204.
  • 8Capello WN, D "Antonio JA, Manley MT, et al. Arc- deposited hydroxyapatite- coated cups: Results at four to seven years [ J ]. Clin Orthop,2005,441:305 - 312.
  • 9Stilling M, Rahbek O, Soballe K. Inferior survival of hydroxyapatite versus titanium- coated cups at 15 years [ J]. Clin Orthop, 2009, 11:2872 - 2879.
  • 10Field RE, Rushton N. Five-year clinical, radiologlcal and postmortem results of the cambridge cup in patients with displaced fractures of the neck of the femur[ J] J Bone Joint Surg Br,2005,10 : 1344 - 1351.

二级参考文献1

同被引文献12

  • 1Spitzer Al.The cemented femoral stem:selecting the ideal patient[J].Orthopedic,2005,28:841-848.
  • 2陈述祥,刘彦.人工全髋关节翻修术的研究进展[J].中国娇形外科杂志,2012,23:2154-2156.
  • 3HughU.The long-term success of modular proximal fixation stemsin revision total hip arthroplasty[J].J Arthroplasty,2002,17:138-141.
  • 4Weiss RJ,Stark A,Karrholm J.A modular cementless stem vs.ce-mented long-stem prostheses in revision surgery of the hip:a popu-lation-based study from the Swedish Hip Arthroplasty Register[J].Acta 0rthop,2011,82:136-142.
  • 5Kang MN,Huddleston JI,Hwang K,et al.Early outcome of a modularfemoral component in revision total hip arthroplasty[J].J Arthroplas-ty,2008,23:220-225.
  • 6Lakstein D,Backstein D,Safir O,et al.Revision total hip arthroplastywith a porous-coated modular stem:5 to 10 years follow-up[J].Clin 0rthop,2010,468:1310-1315.
  • 7Kyoung HM,Kang JS,Lee SH,et al.Revision total hip arthroplasty u-sing an extensively porous coated femoral stem[J].Clin OrthopSurg,2009,1:105-109.
  • 8Kwong LM,Miller AJ,Lubinus P.A modular distal fixation option forproximal bone loss in revision total hip arthroplasty:a 2-to 6-yearfollow-up study[J].J Arthroplasty,2003,3:94-97.
  • 9Salemyr MF,Skoldenberg OG,Bodin HG,et al.Good results with anuncemented proximally HA _ coated stem in hip revision surgery:62hips followed for 2-13 years[J].Acta Orthop,2008,79:184-193.
  • 10Lazarinis S,Karrholm J,Hailer NP.Effects of hydroxyapatite coatingof cups used in hip revision arthroplasty[J].Acta Orthop,2012,83:427-435.

引证文献1

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部