通过对上海御桥生活垃圾焚烧发电厂前后5 a的运行数据的比较,分析了生活垃圾焚烧炉混烧医疗废弃物后运行参数的变化及其系统对运行工况、设备寿命及生产成本的影响。
By comparing with operating data of Shanghai Yuqiao Domestic Waste Incineration Plant in 5 years, changes of operational parameter after the waste incinerator burning domestic waste with medical waste were analyzed, as well as influences of the system on operational situation, life cycle of equipment, and production cost.
出处
《环境卫生工程》
2013年第2期18-20,24,共4页
Environmental Sanitation Engineering
关键词
垃圾焚烧炉
混合焚烧医疗废弃物
燃烧概况分析
设备寿命周期分析
运行成本分析
waste incinerator
burning with medical waste
combustion situation analysis
life cycle analysis of equip- ment
operation cost analysis