期刊文献+

过氧化物交联低密度聚乙烯的结构与性能关系研究 被引量:8

Investigation of the Correlations in the Structures and Properties of
下载PDF
导出
摘要 以过氧化二异丙苯(DCP)为交联剂,考察了温度、时间及DCP用量对交联低密度聚乙烯(XLDPE)结构和性能的影响,建立了结构与性能的关系。研究表明,交联度与交联密度随着DCP用量的增加而增大;当DCP用量超过2.0%,且交联温度和时间分别大于160℃和15 min时,XLDPE的交联度达到最大值;当温度高于450℃时,XLDPE热稳定性较LDPE好,且XLDPE的结晶度、结晶温度及熔融温度随着交联度的增加而下降;XLDPE具有剪切变稠特性,其剪切黏度随着剪切速率和交联度的增加而增大。 With dicumyl peroxide (DCP) as the cross-linking agent, the effects of the temperature, the time and the concentration of DCP on the structures and properties of cross-linked low-density polyethylene (XLDPE) were studied. The relationship between the structures and properties of XLDPE was established. The results indicated that the cross-linking degree and cross-linking density increased with the increase of DCP; and the crosslinking degree of XLDPE reached at its maximum limit beyond 15 min, 160 ℃ and a DCP content of 2.0 wt%. The thermostahility of low-density polyethylene was better than that of LDPE above the temperature of 450 ℃ after cross-linked; it was also concluded that the crystallization degree, the crystallization and melting temperature of the XLDPE decreased with the increase of cross-linking degree. It was found that XLDPE showed a shear thickening character, and its shear viscosity increased with the increase of shear rate and the cross-linking degree.
出处 《塑料工业》 CAS CSCD 北大核心 2013年第5期33-37,共5页 China Plastics Industry
关键词 低密度聚乙烯 交联 过氧化物 热稳定性 流变 LDPE Cross-linking Peroxide Thermostability Rheology
  • 相关文献

参考文献9

  • 1GULMINE J V, AKCELRUD L. Correlations between the processing variables and morphology of crosslinked polyethy- lene [J]. Appl Polym Sci, 2004, 94 (1): 222-230.
  • 2KHONAKDAR H A, MORSHEDIAN J, WAGENKNECHq U, et al. An investigation of chemical crosslinking effect or properties of high-density polyethylene [ J ]. Polymer, 2003, 44 (15): 4301-4309.
  • 3BHATEJA S K, ANDREWS E H. Effect of high-energy radi- ation on the uniaxial tensile creep behaviour of ultra-high mo. lecular weight linear polyethylene [J]. Polymer, 1983, 24(2): 160-166.
  • 4张骥忠,葛铁军.交联剂对化学交联高密度聚乙烯热收缩性能的影响[J].沈阳化工大学学报,2011,25(4):330-334. 被引量:4
  • 5ANDERSSON L H U, HJERTBERG T. The effect of differ- ent structure parameters on the cross-linking behaviour and network performance of LDPE [ J ]. Polymer, 2006, 47 (1) : 200-210.
  • 6FLORY P J, REHNER J. Statistical mechanics of cross- linked polymer networks I. Rubbedike elasticity [ J ].ChemPhys, 1943, 11 (11): 512-520.
  • 7HENDRA P J, PEACOCK A J, WILLIS H A. The morphol- ogy of linear polyethylenes crosslinked in their melts. The structure of melt crystallized polymers in general [ J ]. Poly- mer, 1987, 28 (5): 705-709.
  • 8KRUPA I, LUYT A S. Mechanical properties of un- crosslinked and crosslinked linear low-density polyethylene/ wax blends [J]. Appl Polym Sei, 2001, 81 (4): 973 - 980.
  • 9GHOSH P, DEV D. Reactive processing of polyethylene: Effect of peroxide-induced graft copolymerization of some a- crylic monomers on polymer structure meh theology and relax- ation behavior [ J]. Eur Polym, 1998, 34 (10) : 1539 - 1547.

二级参考文献5

共引文献3

同被引文献81

引证文献8

二级引证文献53