Computer-driven automated weaning reduces weaning duration in difficult-to-wean patients 被引量:3

Computer-driven automated weaning reduces weaning duration in difficult-to-wean patients
原文传递
导出
摘要 Background Weaning difficulties occur in 31% of total intubated patients, and result in prolonged weaning duration. A computer-driven automated weaning system can perform a spontaneous breathing trial (SBT) automatically and display a message when the trial is successfully passed. Such a system might have a beneficial effect on difficult-to-wean patients. The aim of this study was to examine whether the computer-driven automated weaning system can accelerate discontinuation of mechanical ventilation and improve outcomes in difficult-to-wean patients. Methods This randomized controlled study included 39 difficult-to-wean patients who failed their first spontaneous breathing trial. Before initiating weaning, eligible patients were randomly allocated to wean by computer-driven automated weaning system (CDW group, n=19) or a physician-controlled local protocol (PW group, n=20). Weaning duration, defined as the time from inclusion until first extubation, was the primary endpoint. Secondary endpoints were total duration of mechanical ventilation, the length of intensive care unit (ICU) stay, the number of reintubations, the mortality rate in the ICU, the number of noninvasive ventilations, the number of complications in the ICU, and the number of ventilator-associated pneumonia cases. Results The weaning duration was reduced with the computer-driven weaning as compared with the usual protocol (median 29.0 hours vs. 45.5 hours, P=0.044). Total duration of mechanical ventilation and duration of the ICU stay did not differ between the CDW and PW groups. There was no difference in the number of reintubations between the CDW and PW groups (3 and 4 patients, P=0.732). The study groups showed comparable numbers of tracheostomy, self- extubations, ventilator-associated pneumonia, and non-invasive ventilation. Mortality in the ICU was similar in the CDW and the PW groups (21.1% vs. 20.0%, P=0.935). Conclusion The computer-driven automated weaning system can reduce weaning duration in difficult-to-wean patients as compared with a physician-controlled weaninq protocol. Background Weaning difficulties occur in 31% of total intubated patients, and result in prolonged weaning duration. A computer-driven automated weaning system can perform a spontaneous breathing trial (SBT) automatically and display a message when the trial is successfully passed. Such a system might have a beneficial effect on difficult-to-wean patients. The aim of this study was to examine whether the computer-driven automated weaning system can accelerate discontinuation of mechanical ventilation and improve outcomes in difficult-to-wean patients. Methods This randomized controlled study included 39 difficult-to-wean patients who failed their first spontaneous breathing trial. Before initiating weaning, eligible patients were randomly allocated to wean by computer-driven automated weaning system (CDW group, n=19) or a physician-controlled local protocol (PW group, n=20). Weaning duration, defined as the time from inclusion until first extubation, was the primary endpoint. Secondary endpoints were total duration of mechanical ventilation, the length of intensive care unit (ICU) stay, the number of reintubations, the mortality rate in the ICU, the number of noninvasive ventilations, the number of complications in the ICU, and the number of ventilator-associated pneumonia cases. Results The weaning duration was reduced with the computer-driven weaning as compared with the usual protocol (median 29.0 hours vs. 45.5 hours, P=0.044). Total duration of mechanical ventilation and duration of the ICU stay did not differ between the CDW and PW groups. There was no difference in the number of reintubations between the CDW and PW groups (3 and 4 patients, P=0.732). The study groups showed comparable numbers of tracheostomy, self- extubations, ventilator-associated pneumonia, and non-invasive ventilation. Mortality in the ICU was similar in the CDW and the PW groups (21.1% vs. 20.0%, P=0.935). Conclusion The computer-driven automated weaning system can reduce weaning duration in difficult-to-wean patients as compared with a physician-controlled weaninq protocol.
出处 《Chinese Medical Journal》 SCIE CAS CSCD 2013年第10期1814-1818,共5页 中华医学杂志(英文版)
关键词 RESPIRATION artificial WEANING COMPUTERS airway extubation respiration, artificial, weaning, computers, airway extubation
  • 相关文献

参考文献20

  • 1Esteban A, Alia I, Ibanez J, Benito S, Tobin MJ. Modes of mechanical ventilation and weaning: a national survey of Spanish hospitals. Chest 1994; 106: 1188-1193.
  • 2Esteban A, Anzueto A, Frutos F, Alia I, Brochard L,Stewart TE, et al. Characteristics and outcomes in adult patients receiving mechanical ventilation: a 28-day international study. JAMA 2002; 287:345-355.
  • 3Ely EW, Baker AM, Dunagan DP, Burke HL, Smith AC, Kelly PT, et al. Effect on the duration of mechanical ventilation of identifying patients capable of breathing spontaneously. N Engl J Med 1996; 335: 1864-1869.
  • 4Coplin WM, Pierson D J, Cooley KD, Newell DW, Rubenfeld GD. Implications of extubation delay in brain-injured patients meeting standard weaning criteria. Am J Respir Crit Care Med 2000; 161: 1530-1536.
  • 5Stroetz RW, Hubmayr RD. Tidal volume maintenance during weaning with pressure support. Am J Respir Crit Care Med 1995; 152: 1034-1040.
  • 6Dojat M, HarfA, Touchard D, Lemaire F, Brochard L. Clinical evaluation of a computer-controlled pressure support mode. Am J Respir Crit Care Med 2000; 161:1161-1166.
  • 7Lellouche F, Mancebo J, Jolliet P, Roeseler J, Schortgen F, Dojat M, et al. A multicenter randomized trial of computer-driven protocolized weaning from mechanical ventilation. Am J Respir Crit Care Med 2006; 174: 894-900.
  • 8Rose L, Presneill JJ, Johnston L, Cade JF. A randomised, controlled trial of conventional versus automated weaning from mechanical ventilation using SmartCareTM/PS. Intensive Care Med 2008; 34:1788-1795.
  • 9Schadler D, Elke G, Pulletz S, Haake N, Frerichs I, Scholz J, et al. The Effect of automatic weaning with SmartCare/PS on ventilation time in postsurgical patients - A randomized controlled trial. Am J Resoir Crit Care Med 2009: 179: A3646.
  • 10Boles JM, Bion J, Connors A, Herridge M, Marsh B, Melot C, et al. Weaning from mechanical ventilation. Eur Respir J 2007; 29: 1033-1056.

同被引文献9

引证文献3

二级引证文献9

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部