期刊文献+

新型眼球生物测量仪Lenstar的原理及其临床应用 被引量:12

The new laser optical biometer: attributes and applications
原文传递
导出
摘要 Haag—Streit公司推出的新型光学激光生物测量仪Lenstar(晶星)900,是一个将高端激光和角膜厚度、前房深度、晶状体厚度、眼轴长度、角膜曲率、角膜直径、瞳孔大小、光轴的偏心率、视网膜厚度的测量和人工晶状体度数计算结合为一体的新型眼科没备。现就Lenstar的测量原理和临床应用最新进展以及优缺点作一综述。 Haag-Streit's new laser optical biometer called Lenstar 900 provides the user with a complete biometric assessment of the patient's eye in a single measurement procedure, including pachymetry, anterior chamber depth, lens thickness, axial length, keratometry, limbal diameter, pupillometry, eccentricity of the visual axis and retinal thickness. This article provides a basic overview of the underlying measurement principles and describes the clinical application, benefits and limitations of Lenstar.
出处 《中华眼视光学与视觉科学杂志》 CAS 2013年第5期314-317,320,共5页 Chinese Journal Of Optometry Ophthalmology And Visual Science
关键词 光学生物测量仪 LENSTAR 屈光 白内障 人工晶状体 Optical biometer Lenstar Refraction Cataract Intraocular lens
  • 相关文献

参考文献36

  • 1Olsen T. Calculation of intraocular lens power : a review. ActaOphthalmol Scand,2007,85:472-485.
  • 2Hoffer KJ,Shammas HJ,Savini G. Comparison of 2 laserinstruments for measuring axial length. J Cataract Refract Surg,2010,36:644-648.
  • 3Findl 0,Kriechbaum K, Sacu S, et al. Influence of operatorexperience on the performance of ultrasound biometry comparedto optical biometry before cataract surgery. J Cataract RefractSurg,2003,29:1950-1955.
  • 4Buckhurst PJ, Wolffsohn JS, Shah S, et al. A new optical lowcoherence reflectometry device for ocular biometry in cataractpatients. Br J Ophthalmol, 2009,93 : 949-953.
  • 5Holzer MP, Mamusa M, Auffarth GU. Accuracy of a new partialcoherence interferometry analyser for biometric measurements.Br J Ophthalmol, 2009,93 : 807-810.
  • 6Rohrer K, Frueh BE, Walti R, et al. Comparison andevaluation of ocular biometry using a new noncontact opticallow-coherence reflectometer. Ophthalmology ,2009,116 : 2087 -2092.
  • 7Cruysberg LP, Doors M, Verbakel F, et al. Evaluation of theLenstar LS 900 non-contact biometer. Br J Ophthalmol, 2010,94:106-110.
  • 8Schmid GF. Axial and peripheral eye length measured withoptical low coherence reflectometry. J Biomed Opt, 2003,8 :655-662.
  • 9Zysk AM, Nguyen FT, Oldenburg AL, et al. Optical coherencetomography : a review of clinical development from bench tobedside. J Biomed Opt,2007,12:051403.
  • 10Sahin A, Gursoy H, Basmak H, et al. Reproducibility of ocularbiometry with a new noncontact optical low-coherencereflectometer in children, Eur J Ophthalmol ,2011,21 : 194-198.

同被引文献101

引证文献12

二级引证文献31

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部