Brushless Doubly-Fed Induction Machine as a Variable Frequency Transformer
Brushless Doubly-Fed Induction Machine as a Variable Frequency Transformer
摘要
VFT (variable frequency transformer) has been recently used as art alternative to HVDC (high voltage direct current) to control power flow between asynchronous networks. VFT consumes less reactive power than a back-to-back HVDC system, provides faster initial transient recovery, and has better natural damping capability. VFT is simply a DFIM (doubly-fed induction machine) where the machine torque controls the power flow from stator to rotor and vice versa. The main disadvantage of this VFT is the slip rings and brushes required for the rotor circuit, especially in bulk power transmission. The BDFM (brushless doubly-fed machine) with nested cage rotor machine is proved to be a comparable alternative to conventional DFIM in many applications with the advantage that all windings being in the stator frame with fixed output terminals. In this paper, the BDFM is used as a BVFT (brushless variable frequency transformer). A prototype machine is designed and simulated to verify the system validity.
参考文献20
-
1MP. Bahrman, Overview of HYDC transmission, in: 2006 IEEE PES Power Systems Conference and Exposition, Atlanta, 2006, pp. 18-23.
-
2R. Piwko, E. Larsen, Variable frequency transformer-FACTS technology for asynchronous power transfer, in: 200512006 IEEE PES Transmission and Distribution Conference and Exhibition, Dallas, 2006, pp. 1426-1428.
-
3D. Nadeau, A 100-MW variable frequency transformer (VFT) on the Hydro-Quebec Translinergie network-the behavior during disturbance, in: IEEE Power Engineering Society General Meeting, Tampa, 2007, pp. 1-5.
-
4B. Bagen, D. Jacobson, G. Lane, H. Turanli, Evaluation of the performance of back-to-back HYDC converter and variable frequency transformer for power flow control in a weak interconnection, in: IEEE Power Engineering Society General Meeting, Tampa, 2007, pp. 1-6.
-
5P. Truman, N. Stranges, A direct current torque motor for application on a variable frequency transformer, in: IEEE Power Engineering Society General Meeting, Tampa, 2007, pp. 1-5.
-
6A Merkhouf, P. Doyon, S. Upadhyay, Variable frequency transformer-Concept and electromagnetic design evaluation, IEEE Energy Conv. 4 (2008) 989-996.
-
7R. Yuan, Y. Chen, G. Chen, Y. Sheng, Simulation model and characteristics of variable frequency transformers used for grid interconnection, in: IEEE Power & Energy Society General Meeting, Calgary, 2009, pp. 1-5.
-
8E.T. Raslan, AS. Abdel-Khalik, MA Abdulla, MZ. Mustafa, Perf romance of VFT when connecting two power grids operating under different frequencies, in: Conf. PEMD lET, Manchester, UK, 2010, pp. 1-6.
-
9L. Wang, L. Chen, Reduction of power fluctuations of a large-scale grid-connected offshore wind farm using a variable frequency transformer, IEEE Sustainable Energy, 3 (2011) 226-234.
-
10S. Shiyi, E. Abdi, R. McMahon, Low-cost variable speed drive based on a brushless doubly-fed motor and a fractional unidirectional converter, IEEE Ind. Electron. 1 (2012) 317-325.
-
1刘伟,朱世和,秦忆.双馈绕线式异步电动机性能分析[J].华中理工大学学报,1996,24(3):28-30.
-
2李辉,唐显虎,刘志详,夏桂森.5MW双馈风电机组低电压穿越的仿真分析[J].电网与清洁能源,2010,26(12):75-81. 被引量:6
-
3雷竞业.绕线型异步电动机串级调速系统分析[J].中国科技信息,2005(18A):107-107. 被引量:1
-
4张寿珍,金钊,匡立靖.带异步电动机负载时发电机组容量的选择[J].重庆通信学院学报,2000,19(2):25-29.
-
5王巍,贾利群,张宝剑.绕线式异步电动机起动电阻计算方法探析[J].平顶山师专学报,1999,14(2):26-28.
-
6黄群.电容转子异步电动机[J].电气时代,2006(3):84-87. 被引量:2
-
7金秋生.异步电动机的起动能耗与降损措施[J].大众用电,2004(9):32-33.
-
8黄刚,张昌凡.一种用于异步电机矢量控制的新型滑模转子磁链观测器研究[J].动力学与控制学报,2011,9(1):75-78. 被引量:2
-
9邓玉章.一种新型电动机软启动器[J].东方电气评论,2003,17(4):189-192.
-
10黄群.电容转子异步电动机简介[J].电力系统装备,2005(9):90-92.