摘要
该文分析并探讨变电站无功补偿配置的主要原则,结合实际算例,采用无功功率统计法,对220 kV及以下变电站无功补偿容量进行计算分析,经济合理地配置无功补偿设备。此计算方法符合经济补偿原则,在工程实际中可操作性强,计算结果较为准确,供同行参考。
This paper analyzes and discusses the main principles of reactive power compensation configuration in the transformer substation combined with practical examples, using statistical method of reactive power to calculate and analyze reactive power compensation capacity in 220 kV and below substation and configure reactive power compensation equipment economically and reasonably.This calculation method is consistent with economic compensation principle, operable in engineering practice, and more accurate calculations for reference.
出处
《科技创新导报》
2013年第5期46-49,共4页
Science and Technology Innovation Herald
关键词
220kV及以下变电站
无功补偿
无功损耗
统计法
220 kV and below substation reactive power compensation reactive power loss statistical method