期刊文献+

矢量法评价Epi-LASIK对散光的矫正效果及其与视觉质量变化的关系 被引量:1

Vector analysis of correction of astigmatism by Epi-LASIK and the relationship between the result of analysis and the change in visual quality
下载PDF
导出
摘要 目的:采用标准矢量分析法评价准分子激光角膜上皮瓣下磨镶术(epipolis laser in situ keratomileusis,Epi-LASIK)对散光的矫正效果,并探讨其与明视无眩光下对比敏感度函数(contrast sensitivity function,CSF)变化的关系。方法:选取行Epi-LASIK术矫正近视散光的68眼,近视屈光度为-5.00~-9.00D,散光屈光度为-1.00~-3.00D,术后随访6mo。运用美国国家标准学会推荐的标准矢量分析法评估Epi-LASIK术后1,6mo散光的矫正效果。采用CSV-1000E对比敏感度仪检测手术前后最佳矫正视力下明视无眩光时的CSF。结果:术后1mo各空间频率(单位为cycles per degree,c/d)的CSF低于术前(P<0.01),术后6mo时12c/d和18c/d的CSF分别低于术前(P<0.05),术后1mo时的3c/d,6c/d和12c/d CSF分别低于术后6mo(P<0.05);术后1,6mo时的|SIRC|与18c/d的CSF下降呈正相关(r=0.537,0.674,P<0.01);术后1mo的EM为-0.21±0.29,6mo的EM为-0.12±0.31。结论:Epi-LASIK术后6mo内,中高度近视合并中低度散光患者可出现明视无眩光下高频段CSF的下降,其下降原因可能与手术引起的散光矫正量有关。 AIM : To evaluate the outcome of astigmatism correction after epipolis laser in situ keratomileusis(Epi-LASIK) by standardized vector analysis, and to investigate the relatioship between the result of analysis and the change in contrast sensitivity function(CSF). METHODS: Totally 68 myopic astigmatism eyes treated with Epi-LASIK. The myopic diopter was range from -5.00D to -9. 00D, and the astigmatic diopter was range from -1.00D to -3.00D. The following- up period was for 6 months. The outcome of astigmatism correction was evaluated by the standardized vector analysis which was recommended by the American National Standards Institute. The photopic without glare CSF with best spectacle-corrected visual acuity was examined by CSV-1000E. RESULTS: The CSF of all spatial frequency in 1 month postoperatively were significant lower than that preoperatively( P〈 0. 01 ). The CSF of spatial frequency 12c/d (cycles per degree) and 18c/d in 6 months postoperatively were significant lower than thatpreoperatively(P〈0.05). The CSF of 3c/d, 6c/d and 12c/d in 1 month were significant lower than that in 6 months postoperatively(P〈0.05). The I SIRCI ( absolute surgically induced refractive correction) in 1 month, 6 months were positively correlated with the decrease of 18c/d CSF postoperatively ( r= 0. 537, 0. 674, P〈 0.01 ). The error of magnitude(EM) in 1 month was -0.21±0.29 and -0.12±0. 31 in 6 months postoperatively. CONCLUSION: There was decrease in high spatial frequency contrast sensitivity under photopic without glare of myopic and astigmatic eyes with midrange and high diopter within 6 months after Epi-LASIK. The SIRC might have correlation with the decrease in contrast sensitivity.
出处 《国际眼科杂志》 CAS 2013年第6期1099-1102,共4页 International Eye Science
基金 国家自然科学基金资助项目(No.11204277)~~
关键词 矢量分析 散光 准分子激光角膜上皮瓣下磨镶术 对比敏感度 vector analysis astigmatism epipolislaser in situ keratomileusis contrast sensitivity
  • 相关文献

参考文献9

  • 10ndategui JC, Vilaseca M, Arjona M, et al. Optical quality after myopic photorefractive keratectomy and laser in situ keratomileusis: comparison using a double-pass system. J Cataract Refract Surg 2012 ;38 (1) :16-27.
  • 2Kim A, Chuck RS. Wavefront- guided customized cornealablation. Curr Opin Ophthalmol 2008; 19(4) :314-320.
  • 3Fares U, Suleman H, Al-Aqaba MA, et al. Efficacy, predictability, and safety of wavefront-guided refractive laser treatment : metaanalysis. J Cataract Refract Surg 2011 ; 37(8) :1465-1475.
  • 4Wolffsohn JS, Bhogal G, Shah S. Effect of uncorrected astigmatism on vision. J Cataract Refract Surg 2011 ; 37 (3) :454-460.
  • 5瞿佳,吕帆,毛欣杰,毛崇溶.视觉矫正质量评价研究[J].中华眼科杂志,2003,39(6):325-327. 被引量:42
  • 6Eydelman MB, Drum B, Holladay J,et al. Standardized analyses of correction of astigmatism by laser systems that reshape the cornea. J Refract Surg 2006 ; 22 ( 1 ) : 81-95.
  • 7Lee YC, Hu FR, Wang IJ. Quality of vision after laser in situ keratomileusis: influence of dioptric correction and pupil size on visual function. J Cataract Refract Sarg 2003 ; 29 (4) :769-777.
  • 8Alpins N, Stamatelatos G. Clinical outcomes of laser in situ keratomileusis using combined topography and refractive wavefront treatments for myopic astigmatism. J Cataract Refract Surg 2008; 34 (8) :1250-1259.
  • 9Wu F, Yang Y, Dongherty PJ. Contralateral comparison of wavefront- guided LASIK surgery with iris recognition versus without iris recognition using the MELSO Excimer Iaser system. Clin Exp Optom 2009 ; 92 ( 3 ) : 320-327.

共引文献41

引证文献1

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部