期刊文献+

滞环两态电流调节器工作频率分析及控制 被引量:1

Analysis and Control of the Operation Frequency of Two State Hysteresis Current Regulator
下载PDF
导出
摘要 从理论和试验两方面分析了影响电机传动系统中滞环两态电流调节器工作频率的主要因素 .由此提出一种稳频控制技术 ,该技术直接将滞环两态电流调节器的工作频率作为正反馈信号 ,通过动态控制滞环两态电流调节器的滞环宽度随其工作频率成正比变化 ,达到降低变流器直流端输入电压或电机转速变化的影响、稳定滞环两态电流调节器工作频率的目的 .从而极大地提高了电机传动系统的可靠性 ,并且抑制了其可能出现的混沌运动现象 . The main reasons to affect the operation frequency of two state hysteresis current regulator for motor control system are analyzed by theory and experiment. A control technique of stabling frequency for two state hysteresis current regulator is developed, it decreases the effect of input DC voltage of converter and motor speed on the operation frequency of two state hysteresis current regulator by taking the operation frequency as the positive control signal and varing dynamically the hysteresis width of two state hysteresis current regulator with its operation frequency. The feasible theoretical and experimental results demonstrate that the reliability of motor control system is greatly increased and its possible chaotic operations will be restricted.
出处 《华南理工大学学报(自然科学版)》 EI CAS CSCD 北大核心 2000年第9期22-26,共5页 Journal of South China University of Technology(Natural Science Edition)
基金 国家自然科学基金资助项目!(597770 0 8) 广东省自然科学基金资助项目!(980 579)
关键词 滞环两态电流调节器 控制 工作频率 电机 调速 two state hysteresis current regulator stabling frequency control chaos
  • 相关文献

参考文献4

  • 1陈伯时.电力拖动自动控制系统[M].北京:机械工业出版社,1990.130-130.
  • 2周士鸿.频率-电流转换电路[J].电气传动和自动控制,1989,2(3):11-12.
  • 3陈伯时,电力拖动自动控制系统,1990年,130页
  • 4周士鸿,电气传动和自动控制,1989年,2卷,3期,11页

共引文献5

同被引文献40

  • 1Yang S M,Lee C H.A deadbeat current controller for field oriented induction motor drives[J].IEEE Transactions on Power Electronics,2002,17(5):772 -778.
  • 2Bu J R,Xu L Y.A new deadbeat fuzzy algorithm for current regulated PWM without rotating reference frame transformation[A].Proceedings of the 24th Annual Conference of the IEEE Industrial Electronics Society[C].Germany:Aachen IECON'98,1998.
  • 3Ottersten R,Svensson J.Vector current controlled voltage source converter-deadbeat control and saturation strategies[J].IEEE Transactions on Power Electronics,2002,17(2):279-285.
  • 4Malesani L,Mattavelli P,Buso S.Robust dead-beat current control for PWM rectifiers and active filters[J].IEEE Transactions on Industry Applications,1999,35(3):613-620.
  • 5Nishida K,Nakaoka M.Deadbeat current control with adaptive predictor for three-phase voltage-source active power fllter[A].IEEE 35th Annual Conference on Power Electronics Specialists Conference[C].Germany Aachen:PESC,2004.
  • 6WangDZ,WangZL,GuSS.Identification and control of induction motor using artificial neural networks[A].Proccedings of the Fifth International Conference on Electrical Machines and Systems[C].Shenyang:ICEMS 2001,2001.
  • 7BurtonB,HarleyRG,DianaG,etal.Implementation of a neural network to adaptively identify and control VSI-Fed induction motor stator currents[J].IEEE Transactions on Industry Applications,1998,34(3):580-588.
  • 8BurtonB,KamranF,HarleyRG,etal.Identification and control of induction motor stator currents using fast on-line random training of a neural network[J].IEEE Transactions on Industry Applications,1997,33(3):697-704.
  • 9Ping H W,Rahim N A.Vector control of induction motor using a hybrid neural network/fuzzy logic model[A].International Conference on Power System Technology[C].Australia:Perth,2000.
  • 10Seidl D R,.Kaiser D A,Lorenz R D.One-step optimal space vector PWM current regulation using a neural network[A].Conference Record of the 1994 IEEE Industry Applications Society Annual Meeting[C].USA:Denver,IEEE,1994.

引证文献1

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;