摘要
设计唐都医院生殖医学中心的净化空调系统,介绍该生殖医学中心的布局,包括实验室部分、门诊部分和办公辅助部分;环境要求,包括净化级别、温湿度、噪声等;空调送回风的平面布置;空调设备的布置,包括空气处理机组和新风机组;冷、热源和水系统等。
The purification air conditioning design of reproductive medical center in TangDu hospital was conducted. Introduce the composition of the center, including laboratory rooms, clinic rooms and offices; environment requirements, including purification level, air temperature, relative humidity and noise; the plane arrangement of air conditioning pipe; the set of equipments, including ATU and fresh air handling unit; cooling/heating source and water system.
出处
《洁净与空调技术》
2013年第2期42-45,共4页
Contamination Control & Air-Conditioning Technology
关键词
生殖医学中心
净化
空调设计
Reproductive medical center
Purification
Air conditioning design