期刊文献+

用汽动给水泵代替电泵方式启停600MW机组分析探讨 被引量:2

Analysis of 600 MW Unit Started and Stopped with the way of Steam Feed Pump Instead of Electrically Driven Feed Pump
下载PDF
导出
摘要 目前国产600MW超临界机组电厂均设计用电动给水泵启停机组,能耗高。文章以一个2×600 MW超临界机组电厂为例,用汽泵代替电泵方式启停机组进行分析探讨,可供同类机组借鉴。 Homemade 600 MW supererifieal unit power plant design the unit started and stopped with the way of electrically driven feed pump, which exists the problem of high energy consumption. Taking example of 2 × 600 MW supercritical unit, the paper analyzes the unit started and stopped with the way of steam feed pump instead of electrically driven feed pump for refer- ence to the similar unit.
作者 覃恒锋
出处 《企业科技与发展》 2013年第6期102-103,112,共3页 Sci-Tech & Development of Enterprise
关键词 超临界机组 汽动、电动给水泵 冷态启动 热态启动 滑参数停机 supercritieal unit steam feed pump electrically driven feed pump cold start hot start smooth parameters clos- ing-down
  • 相关文献

参考文献3

  • 1东方汽轮机厂.N600-24.2/566/566型汽轮机运行说明书、安装说明书[Z].
  • 2国家电力公司华东公司.发电厂集控运行技术问答[M].北京:中国电力出版社,2003.