摘要
结合原苏联热力计算标准和我国《电站锅炉水动力计算方法 (JB/Z2 0 1 -83)》,对电厂过热器系统热偏差计算问题进行了探讨。在吸收我国科研工作者关于沿集箱轴向流量偏差和同屏辐射热量偏差的研究成果的基础上 ,完善了过热器系统热偏差的计算方法 ,对提高我国机组设计水平 ,保证机组安全运行有重要意义。
The paper makes an important on the heat deviation calculation based on the Soviet standard of thermal calculation, the national standard of the boiler hydrodynamics calculation (JB/Z201 83) and the scientific research results on the flow deviation along the box axis and the radiant heat deviation in the same board. The method is more accurate and is of great value to the design and operation security of generations.
出处
《现代电力》
2000年第3期6-11,共6页
Modern Electric Power
关键词
锅炉
过热器系统
热偏差
计算方法
boiler
super heater
flow deviation
heat deviation
calculation method