自动管电流调制下不同管电压、噪声指数对体模不同体厚辐射剂量的影响 被引量:4

Effect of different tube voltage and noise index on radiation dose of different body thickness in phantom using tube current automatic regulation technology
原文传递
导出
摘要 目的探讨使用自动管电流调制技术下,不同管电压、噪声指数选择对体模不同体厚辐射剂量的影响。方法使用自制锥形体模,进行分段扫描,以实现对不同体厚患者的模拟,利用自动管电流调制技术,分别调整噪声指数(noise index,NI)(10~20)及管电压(80~140 kV),记录容积CT剂量指数(volume computed tomography dose index,CTDIvol)。结果平均体厚<126.2 mm,噪声指数10~12,管电压80 kV,CTDIvol最低,噪声指数12~20,管电压使用120 kV,CTDIvol最低,平均体厚≥126.2 mm,噪声指数在10~20,管电压使用120 kV,CTDIvol最低;并建立回归方程:CTDIvol=0.511+0.081×厚度-0.709×噪声指数+0.004×电压,对总体模型、厚度系数及噪声指数系数进行检验,P值均<0.001,对截距及电压系数进行统计学检验,P值分别为0.487、0.415。结论使用自动管电流调制技术,辐射剂量(CTDIvol)随扫描厚度的增加而增加,随噪声指数的增加而降低,与管电压没有明显相关性,但通过数据观察,在成人体厚范围,使用管电压120 kV,能够实现辐射剂量的降低。 Objective To evaluate the effect of different tube voltage and noise index on radiation (lose of different body thickness in phantom using tube current automatic regulation technology. Methods Home-made cone phantom was used for segmental scanning in order to simulate patients with different body thickness. Using tube current automatic regulation technology, the noise index (10 -20) and tube voltage (80- 140 kV) were adjusted, respectively, and volume computed tomography dose index (CTDIvol) was recorded. Results When the average body thickness was less than 126.2 mm, CTDIvol was the lowest either the noise index was 10 - 12 and tube voltage was 80 kV or the noise index was 12 - 20 and tube voltage was 120 kV. When the average body thickness was not less than 126.2 mm, CTDIvol was the lowest if the noise index was 10 -20 and tube voltage was 120 kV. The regression equation was established: CTDIvol =0.511 + 0.081 thickness - 0. 709 ( noise index) + 0.004 voltage. The coefficients of overall model, body thickness and noise index were all tested ( P 〈 0. 001 ), and the coefficients of distance and voltage were also analyzed (P =0. 487, 0. 415). Conclusion Using tube current automatic regulation technology, the radiation dose (CTDIvol) increases with the increase of the phantom thickness, and decreases with the increase of the noise index. Although there is no significant correlation between CTDIvol and tube voltage, the radiation dose can be reduced by using tube voltage of 120 kV within the range of adult body thickness.
出处 《第三军医大学学报》 CAS CSCD 北大核心 2013年第13期1394-1397,共4页 Journal of Third Military Medical University
关键词 自动管电流调制技术 噪声指数 体厚 管电压 辐射剂量 current automatic regulation technology noise index body thickness tube voltage radi-ation dose
  • 相关文献

参考文献2

二级参考文献12

  • 1李真林,杨志刚,郭应坤,余建群,李媛,陈宪,谈伟.管电流调制技术在多层螺旋CT胸部检查中的应用评价[J].中国医学影像技术,2006,22(6):858-860. 被引量:7
  • 2Kalra MK, Maher MM, Toth TL, et al. Strategies for CT radiation dose optimization. Radiology, 2004,230(3):619-628.
  • 3Kalra MK, Maher MM, Toth TL, et al. Teehniques and applications of automatic tube current modulation for CT. Radiology, 2004,233(3) : 649-657.
  • 4Johnson PT, Fishman EK. IV contrast selection for MDCT: current thoughts and practice. Am J Roentgenol, 2006, 186(2) :406- 415.
  • 5Kalra MK, Maher MM, Toth TL, et al. Comparison of Z-axis automatic tube current modulation technique with fixed tube current CT scanning of abdomen and pelvis. Radiology, 2004,232(2) :347- 353.
  • 6Kalra MK, Rizzo S, Maher MM, et al. Chest CT performed with z-axis modulation: scanning protocol and radiation dose. Radiology, 2005,237(1) :303-308.
  • 7Rizzo S, Kalra M, Schmidt B, et al. Comparison of angular and combined automatic tube current modulation techniques with constant tube current CT of the abdomen and pelvis. Am J Roentgenol, 2006,186(3):673 679.
  • 8Payne JT. CT radiation dose and image quality. Radiol Clin North Am, 2005,43(6) :953-962.
  • 9Frush DP, Applegate K. Computed tomography and radiation understanding the issues. J Am Coll Radiol, 2004, 1(2):113-119.
  • 10全冠民,袁涛,雷建明,杨桦耿,左军.多层螺旋CT对下颈部病变的诊断价值[J].临床放射学杂志,2008,27(1):19-23. 被引量:6

共引文献55

同被引文献37

  • 1Lumsdaine W, Enninghorst N, Hardy BM, et al. Patterns of CTuse and surgical intervention in upper limb periarticular fracturesat a level-1 trauma centre. Injury, 2013, 44(4) : 471-474.
  • 2Lee EJ, Lee SK, Agid R, et al. Comparison of image quality andradiation dose between fixed tube current and combined automatictube current modulation in craniocervical CT angiography. AJNRAm J Neuroradiol, 2009, 30(9) : 1754-1759.
  • 3Mayer C, Meyer M,Fink C, et al. Potential for radiation dosesavings in abdominal and chest CT using automatic tube voltageselection in combination with automatic tube current modulation.AJR Am J Roentgenol, 2014, 203(2) : 292-299.
  • 4Gleeson TG, Byrne B, Kenny P, et al. Image quality in low-dosemultidetector computed tomography: A pilot study to assess fea-sibility and dose optimization in whole-body bong imagine. CanAsso Radiol J, 2010, 61(5) :258-264.
  • 5Rogers LF. Dose reduction in CT : How low can we go? AJR AmJ Roentgenol, 2002,179(2):299.
  • 6Kalra MK, Maher MM, Kamath RS, et al. Sixteen-detector rowCT of abdomen and pelvis: Study for optimization of Z-axis modu-lation technique performed in 153 patients. Radiology, 2004, 233(1):241-249.
  • 7Winklehner A, Goetti R, Baumueller S, et al. Automated at-tenuation-based tube potential selection for thoracoabdominalcomputed tomograghy angiography: Improved dose effective-ness. Invest Radiol, 2011,46(12) :767-773.
  • 8冯琦,龚红霞,庄治国,殷焱,沈云,高娜,许建荣.自动毫安低剂量CT扫描对结肠病变的显示及其对图像质量的影响[J].中华放射学杂志,2008,42(10):1022-1025. 被引量:35
  • 9袁知东,刘鹏程,王成林,邹立秋,陈星,刘远健,刘晓杰,冯飞.噪声关联Z轴管电流调制技术降低多层CT胸部扫描辐射剂量的作用[J].中华放射学杂志,2008,42(11):1196-1200. 被引量:31
  • 10臧晨宏,张敬,张云亭.自动毫安低管电压技术在头颈部血管造影中应用的可行性研究[J].天津医科大学学报,2010,16(2):322-325. 被引量:18

引证文献4

二级引证文献13

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部