摘要 采用循环伏安法在Co2+、Fe3+、K3Fe(CN)6共存的溶液将CoHCF/PB复合膜修饰于过氧化聚吡咯修饰的复合陶瓷碳电极表面(PPyox-CoHCF/PB/CCE)。采用扫描电镜(SEM)方法对修饰电极进行表征,并研究了修饰电极对H2O2的电催化活性。结果表明:PPyox膜的存在更易于Co-HCF/PB在其上的固载、改善了电极表面金属铁氰化物的分散性与修饰电极的电催化活性。在优化的实验条件下,安培法检测H2O2的线性范围为6.0×10-6~4.0×10-3mol.L-1,检出限为3.0×10-6mol.L-1(3 Sb,n=10)。 A CoHCF/PB film was electrodeposited on the surface of PPyox/CCE in a solution containing Co^2+ , Fe^3 + and K3 Fe (CN) 6 using cyclic voltammetry. The morphology of the modified electrode was characterized by scanning electron microscopy (SEM) experiments, and the electrocatalytic performance of the PPyox/CoHCF/PB/CCE modi- fied electrode was investigated. The results showed that the existence of PPyox was favored to the deposition of com- pact and uniform CoHCF/PB film with good adhering. Under the optimum condition, the reduction peak current of the modified electrode was proportional to the concentration of H202 in the range of 6.0 × 10 -6 to 4.0 × 10 -3 mol·L-a with a detection limit of 3.0 × 10-6 mol · L-1 (3 Sb,n = 10).
出处 《延安大学学报(自然科学版)》 2013年第2期86-89,共4页 Journal of Yan'an University:Natural Science Edition
基金 延安市科技攻关项目(2012kg-01)
关键词 铁氰化钴 普鲁士蓝 过氧化聚吡咯 膜修饰电极 电沉积 cobalt hexacyanoferrate prussian blue overoxidized polypyrrole film modified electrode electrodepo-sition
  • 相关文献

参考文献14

  • 1Arduini F,Cassisi A,Amine A,et al. Electrocatalytic oxida-tion of thiocholine at chemically modified cobalt hexacyano-ferrate screen 一 printed electrodes [ J]. J Electroanal Chem,2009,626(1 -2) : 66 -74.
  • 2Abbaspour A, Khajehzadeh A, Ghaffarinejad A. Electrocata-lytic oxidation and determination of hydrazine on nickelhexacyanoferrate nanoparticles - modified carbon ceramic e-lectrode[ J]. J Electroanal Chem,2009,631 (1 -2) : 52 -57.
  • 3余淑娟,张云怀,肖鹏,李小玲,蒙晓琴,杨雁南.基于纳米铁氰化镍修饰二氧化钛纳米管阵列电极的非酶葡萄糖传感器[J].分析化学,2012,40(2):313-316. 被引量:6
  • 4Benesetto G E D, Cataldi T R I. Highly - stabilized polynu-clear indium - hexacyanoferrate film electrodes modified byruthenium species [ J]. Langmuir, 1998,14 ( 21 ) : 6274 -6279.
  • 5刘海燕,王艳玲,张国荣.铁氰化镍/银复合无机膜修饰电极对肼的催化氧化作用[J].分析科学学报,2003,19(4):330-332. 被引量:7
  • 6王飞,于浩,金君,宋诗稳,廉园园,刘珍叶,齐广才.铁氰化钴/铁复合膜修饰电极的制备及应用[J].江西师范大学学报(自然科学版),2011,35(6):556-559. 被引量:1
  • 7Lange U, Roznyatovskaya N V, Mirsky V M. Conductingpolymers in chemical sensors and arrays [ J]. Anal ChimActa,2008,614 (1) : 1-26.
  • 8Witkowski A,Freund M S, Brajtertoth A. Effect of electrodesubstrate on the morphology and selectivity of overoxidizedpolypyrrole films [ J]. Anal Chem, 1991, 63 ( 6 ) ; 622 -626.
  • 9Jiang X H,Lin X Q. Overoxidized polypyrrole film directedDNA immobilization for construction of electrochemical mi-cro -biosensors and simultaneous determination of serotoninand dopamine[ J]. Anal Chim Acta,2005,537( 1 -2) ; 145-151.
  • 10Fernandez I, Trueba M, Nuez C A. Some features of theoveroxidation of polypyrrole synthesized on austenitic stain-less steel electrodes in aqueous nitrate solutions [ J]. SurfCoat Technol,2005,191(1) : 134 -139.

二级参考文献27

  • 1胡军福.碳纳米管粉末微电极对儿茶酚的电催化还原[J].江西师范大学学报(自然科学版),2005,29(2):134-135. 被引量:1
  • 2Ojani R, Raoof J B, Norouzi B. Cu(II) hexacyanoferrate(III) modified carbon paste electrode; application for electroeatalytic detection of nitrite [J]. Electroanalysis, 2008, 20(18): 1996-2002.
  • 3Wang J, Saneheznchez, Arribas A. Biocatalytically induced for mation of cupric ferrocyanide nanoparticles and their application for electrochemical and optical biosensing of glucose [J].Small, 2006, 2(1): 129-134.
  • 4Cui Xingpin, Lin Xiangqin. Hybrid copper-cobalt hexacyanoferrate films modified glassy carbon electrode as an electrochemical sensor for hydrogen peroxide [J]. Analytical Letters, 2002, 35(4): 663-675.
  • 5Liu Y, Teng H, Hou H Q, You T Y. Biosens. Bioelectron. , 2009, 24(11) : 3329-3334.
  • 6YU Jian-Guo, LI Jian-Ping. Chinese J. Anal. Chem., 2008, 36(9): 1201-1206.
  • 7Yang J, Zhang W D, Gunasekaran S. Biosens. Bioelectron. , 2010, 26(1) : 279-284.
  • 8Chen J, Zhang W D, Ye J S. Electrochem. Commun. , 2008, 10(9) : 1268-1271.
  • 9Ding Y, Wang Y, Su L, Bellagamba M, Zhang H, Lei Y. Biosens. Bioelectron. , 2010, 26(2): 542-548.
  • 10Wang X Y, Zhang Y, Banks C E, Chen Q Y, Ji X B. Colloid Surface B, 2010, 78(2): 363-366.

共引文献11

同被引文献18

  • 1CLARK L C Jr, LYONS C. Electrode systems for continuous monitoring in cardiovascular surgery [ J ]. Annals of the New York Academy of Sciences, 1962, 102:29-45.
  • 2WANG J. Electrochemical glucose biosensors [J]. Chem Rev, 2008, 108(2): 814-825.
  • 3KAUSHIK A, KHAN R, SOLANKI P R, et al. Iron oxide nanopartieles-chitosan composite based glucose biosensor [ Jl. Biosens Bioelectron, 2008, 24(4): 676-683.
  • 4YANG J, LIN M, CHO M, et al. Determination of hydrogen peroxide using a Prussian Blue modified macroporous gold electrode [ J ]. Microchim Acta, DOI : 10. 1007/s00604 - 014 - 1433 - 0.
  • 5HUANG X J, LI C C, GU B, et al. Controlled molecularly mediated assembly of gold nanooctahedra for a glucose biosensor [ J]. J Phys Chem C, 2008, 112(10) : 3605 -3611.
  • 6ZHOU K F, ZHU Y H, YANG X L, et al. Electrocatalytic oxidation of glucose by the glucose oxidase immobilized in graphene- Au-Nafion biocomposite [ J ]. Electroanal, 2010, 22 (3) : 259 - 264.
  • 7LAUREYN W, SARA M, FRIEDT J M, et al. Realization and characterization of porous gold for increased protein coverage on aeoustic sensors [ J]. Anal Chem, 2004(15) : 4299 -4306.
  • 8YIN H M, ZHOU C Q, XU C X,et al. Aerobie oxidation of D-glucose on support-free nanoporous gold [ J ]. J Phys Chem C, 2008, 112:9673-9678.
  • 9LIU Z, SEARSON P C. Single nanoporous gold nanowire sensors [J]. J Phys Chem B, 2006, 110(9) : 4318 -4322.
  • 10WANG X, LIU X Y, YAN X L, et al. Enzyme-nanoporous gold biocomposite: excellent biocatalyst with improved biocatalytic performance and stability [J]. PLoS ONE, 2011, 6(9) : e24207.