摘要
在总结前人研究的基础上,综述了开式地表水源热泵系统方案设计要求,认为可以从技术、经济和环保性三方面分析江水源热泵的可行性。重庆江水水量、水温等水质参数完全满足机组要求,为了确保江水源热泵在重庆地区的技术适用性,重点在于寻找解决含砂量过高的技术方案。同时,合理设计的水源热泵系统具有较好的经济性能,尾水排放对江水的污染较小,满足经济环保性要求。认为江水源热泵系统在重庆地区具有较强的可行性及适用性。
This review summarized the design requirements of open type surface water source heat pump system. Technical, economic and environmental can be considered as the three aspects of the river water source heat pump feasibility analysis. The river water temperature, quantity and other characteristics can meet the requirement of the water source heat pump. In order to ensure the river water source heat pump technology suitability, the key technology is looking for solutions to reduce the sand content. Reasonable design of the water source heat pump system has good e cooomic performance and the tail water discharge can cause less water pollution. The river water source heat pump system has strong feasibility and applicability in Chongqing.
出处
《制冷与空调(四川)》
2013年第3期221-225,共5页
Refrigeration and Air Conditioning
关键词
可再生能源
开式江水源热泵
适用性
renewable energy
open type river water source heat pump
applicability