摘要 利用有限元软件ABAQUS建立了包含部分梁、柱的约束PEC柱子结构温度场和力学分析模型,应用约束PEC柱的抗火试验数据验证了模型的合理性。对轴力作用下子结构在火灾下的受力性能进行了参数分析,分析了轴力比、轴向约束刚度、约束梁跨度、柱长度以及材料强度对子结构轴向位移和轴力的影响规律。结果表明:随着轴力比的增加,柱轴向变形峰值和轴力变化系数峰值减小;随着轴向约束的增加,柱轴力变化系数峰值增大,轴向位移峰值减小,高温压缩阶段的轴向位移趋于平缓;随着柱长度的增加,轴向位移峰值和轴力变化系数峰值略有增加;约束梁跨度、型钢屈服强度和混凝土抗压强度对柱轴向位移和轴力变化系数影响很小。 By using the software ABAQUS,a finite element model was established to calculate the temp erature field and mechanical behavior of the sub-structures including partial beams and retrained PEC columns,then the model was verified by fire test data.The verified model was used to analysis the behavior of the sub-structure subjected to axial load under fire condition,including influence of axial load ratio,axial restraint stiffness,retrained beam span,column length and materials strength on the axial displacement and the axial force.It can be seen from the research results that the axial displacement and the axial force enhancement coefficient decrease due to an increase of the axial load ratio.The increasing of axial restraint stiffness lead to a higher peak value of the enhancement coefficient and lower axial displacement,then the axial displacement reduce gently when the column is compressed.The augment of column length induces a slightly increase in the axial displacement and the axial force enhancement coefficient,while the retrained beam span,steel yield strength,concrete compression strength have little influence.
出处 《消防科学与技术》 CAS 北大核心 2013年第7期707-711,共5页 Fire Science and Technology
基金 国家自然科学基金“基于子结构模型的约束PEC柱火灾全过程性能及抗火设计方法研究”(51278321) 江苏省“青蓝工程”中青年学术带头人项目(2010-27) 江苏省“333工程”中青年学术带头人项目(2011-34) 江苏省普通高校研究生科研创新计划项目(CXZZ11_0953)
关键词 约束PEC柱 子结构 受火性能 参数分析 restrained PEC column sub-structure fire performance parametric study
  • 相关文献

参考文献11

二级参考文献62

共引文献406

同被引文献23

  • 1JGJ138-2001型钢混凝土组合结构技术规程[S].北京:中国建筑工业出版社,2001.
  • 2Wald F, Simoes da Silva L, Moore D B. Experimental behavior of a steel structure under natural fire[J]. Fire Safety Journal, 2006,41 (7) :509-522.
  • 3Correia A M, Rodrigues J P C. Fire resistance of partially encased steel columns with restrained thermal elongation[J]. Journal of Constructional Steel Research, 2011,67 (4) : 593- 601.
  • 4Han L H, Wang W H, Yu H X. Analytical behavior of RC beam to CFST column frames subjected to fire[J]. Engineering Structures, 2012,36:394-410.
  • 5WAINMAN D E, TOMLINSON L N. BS476: Part 21, Fire resistance tests-summary of data obtained during tests on web encased columns[R]. 1994.
  • 6KORZEN M, RODRIGUES J P C, CORREIA A M. Composite columns made of partially encased steelsections subjected to fire. Structures in Fire [R]. Proceedings of the Sixth International Conference, 2010: 341-348.
  • 7CORREIA A M, RODRIGUES J P C. Fire resistance of partially encased steel columns with restained thermal elongation [J]. Journal of Construc- tional Steel Research, 2011, 67: 593-601.
  • 8European Committee for Standardization. ENV1993-1-2 Eurocode 3, Design of Steel Structures[S], 1993.
  • 9European Committee for Standardization. ENVI994-1-2 Eurocode 4, Design of Composite and Concrete Structures[S}, 1994.
  • 10M J TERRO. Numerical modeling of the behavior of concrete structures in fire[J]. ACI Structural Journal, 1998, 95 (2) :183-193.

引证文献6

二级引证文献14

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部