半剂量^(99m)Tc-MIBI双时相断层显像在乳腺肿块诊断中的价值 被引量:1

Diagnostic value of half the radiation dose double-phase ^(99m)Tc-MIBI tomographic imaging in breast lesions
下载PDF
导出
摘要 目的研究半剂量99mTc-MIBI双时相断层显像在乳腺肿块诊断中的价值。方法选择220例乳腺肿块患者,随机分为半剂量组(99mTc-MIBI注射剂量370 MBq)和传统剂量组(99mTc-MIBI注射剂量740 MBq),行99mTc-MIBI双时相断层显像。分别计算乳腺肿块早期相、延迟相的放射性比值(T/NT),并对乳腺癌的诊断效率进行比较。结果半剂量组良性病变患者早期相T/NT高于延迟相T/NT(P<0.05),恶性病变患者早期相T/NT高于良性病变患者(P<0.05)。传统剂量组良性病变患者早期相T/NT高于延迟相T/NT(P<0.05),恶性病变患者早期相T/NT高于良性病变患者(P<0.05)。两组早期相、延迟相T/NT比较差异均无统计学意义。两组对乳腺癌的灵敏度、特异性、准确性差异无统计学意义。结论半剂量99mTc-MIBI双时相断层显像在乳腺肿块的诊断中具有良好的图像质量,不影响临床疾病的诊断,且辐射剂量减少一半。 Objective To study the diagnostic value of half the radiation dose double-phase 99mTc-MIBI tomographic imaging in breast lesions.Methods A total of 220 patients with breast lesions were randomly divided into half the radiation dose group(99mTc-MIBI injected dose was 370 MBq) and the conventional dose group(99mTc-MIBI injected dose was 740MBq).All patients underwent double-phase 99mTc-MIBI tomographic imaging in breast lesions.The early phase and delayed phase of radioactivity ratio(T/NT) of breast lesions were calculated separately,and the diagnostic efficiency of breast cancer was compared.Results The early phase T/NT in half the radiation dose group of patients with benign lesions was higher than the delay phase T/NT(P〈0.05),and the early phase T/NT in patients with malignant lesions was higher than that in patients with benign lesions(P〈0.05).the early phase T/NT in the conventional dose group of patients with benign lesions was higher than the delay phase T/NT(P〈0.05),and the early phase T/NT in patients with malignant lesions was higher than that in patients with benign lesions(P〈0.05).T/NT comparative differences had no statistical significance in two groups between the early phase and the delayed phase(P〈0.05).The sensitivity,specificity and accuracy of breast cancer had no statistically significant difference in two groups(P〈0.05).Conclusion Half the radiation dose double-phase 99mTc-MIBI tomographic imaging in breast lesions has good image quality,and it doesn't affect the clinical diagnosis and reduce half of radiation dose.
出处 《山东医药》 CAS 2013年第26期9-11,共3页 Shandong Medical Journal
基金 湖南省科技厅基金资助项目(06sk3057)
关键词 一半剂量 99M锝甲氧基异丁基异腈 乳腺肿瘤 half the radiation dose 99mTc-MIBI breast neoplasms
  • 相关文献

参考文献8

  • 1李少婷,许忠扬.当前医院核技术应用项目环境影响评价中有关问题的探讨[J].核安全,2010,9(1):46-50. 被引量:5
  • 2李少林,王荣福.核医学[M].7版.北京:人民卫生出版社,2008:88.
  • 3Primak AN, Ramirez-Girado JC, Liu X, et al. Improved dual-energy material discrimination for dual-source CT by means of additional spectral filtration[J]. Med Phys,2009,36(4) :1359-1369.
  • 4Christner JA, Zavaletta VA, Eusemann CD, et al. Dose reduction in halical CT: dynamically adjustable z-axis X-ray beam collimation [ J ]. A JR Am J Roentgeno1,2010,194 ( 1 ) :49-55.
  • 5Farrelly C, Davarpanah A, Keeling AN, et al. Low dose dual- source CT angiography of the thoracic aorta [ J ]. Int J Cardiovasc Imaging,2011,27 (7) : 1025-1034.
  • 6高前宁.低剂量扫描在儿童头部检查中的应用价值[J].现代预防医学,2012,39(19):4986-4987. 被引量:2
  • 7Zafrir N. Feasibility of myocardial perfusion imaging with half the radiation dose using ordered-subset expectation maximization with resolution recovery software[ J]. J Nucl Cardiol, 2012,19 (4) :704- 712.
  • 8柳澄.重视CT临床应用中降低辐射剂量的措施[J].中国医疗器械信息,2011,17(10):19-23. 被引量:7

二级参考文献18

共引文献30

同被引文献7

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部