摘要
地下室现浇混凝土外墙因受现场条件限制而采用单侧支模施工时,外墙单侧模板支撑体系是影响质量的关键,在制定方案和实际施工中必须进行重点控制。本工程地下室外墙采用单侧支模施工,在施工中采取一系列的技术措施,取得了较好的效果。
Basement concrete wall because of the limitation conditions of the site and the unilateral formwork construction, exterior unilateral formwork supports system is affecting the quality of the key, making plan and the actual construction must focus control. The basement of the external unilateral formwork construction, taking a series of technical measures in the construction, and achieved good results.
出处
《建筑技术》
2013年第8期713-715,共3页
Architecture Technology
关键词
单侧模板
模板支设
混凝土
模板体系
unilateral formwork
formwork erection
concrete
formwork system