上海地区正常成人第1秒用力吸气容积正常值及预计方程式的探索

Exploration on the reference values and predicted equation of FIV, in normal adults in Shanghai
原文传递
导出
摘要 目的探索上海市正常人群第1秒用力吸气容积(forced inspiratory volume in one second,FIV1)的预计值和医学参考值范围。方法对上海地区521名健康成年人,采用德国耶格公司生产的MasterScreendiffusion(SN:694855)型肺功能仪测定FIV1,探索正常人群FIV。的预计值和医学参考值范围,分析正常人群FIV1与年龄、体质量以及身高的相关性。结果肺功能参数FIV。与身高和年龄呈正相关,但FIV,与身高的关系最为密切,与体质量无关。正常成年男性FIV1预计值的回归方程为FIV1=-5.3510.061*身高-0.027*年龄(身高、年龄P〈0.001,体质量P〉0.05),医学参考值范围为2.1075~4.959l;正常成年女性FIV1预计值的回归方程为FIV1=-2.457+0.04*身高-0.025*年龄(身高、年龄P〈0.001,体质量P〉0.05),医学参考值范围为1.2783~3.5171。结论FIV1值与身高和年龄有关,建立并推荐上海地区使用本成人FIV1正常预计值。 Objective To investigate the predicted value and clinical reference range of the FIV1 in the normal adults in Shanghai. Methods A survey in 521 healthy adults was carried out in Shanghai. FIVI was measured by using Yager Master Screen difiusion(SN:694855). Explore the reference value and medical reference range. Analyse the relative on the FIV1 and age,weight,height in nomal adults. Results The lung functional parameter FIV1 have positive correlation with height and age, and the height and FIV1 reahe closely. While, FIV1 is not related to the weight. The FIV1 predicted equation of normal adult males is FIV1 = -5. 351+0.061* height -0. 027 1 age (height,age, P 〈10. 001,weight, P 〉0.05), medical reference range is 2. 107 5 1, 4. 959 1. The FIV1 predicted equation of normal adult females is FIV1 -2.457+0.041* height 0.0251 age (height,age, P〈0.001,weight, P〉0.05), medical reference range is 1. 278 3 - 3. 517 1. Conclusions FIV1 is related to height and age. The Reference Values and Predicted Equation of normal adults is established and recommended in Shanghai area.
出处 《国际呼吸杂志》 2013年第15期1158-1161,共4页 International Journal of Respiration
基金 本研究属上海市浦东新区科技发展基金创新资金资助项目(PKJ2012-Y12)
关键词 肺通气 第1秒用力吸气容积 成人 预计值 Pulmonary ventilation Forced inspiratory volume in one second Adult Predicted values
  • 相关文献

参考文献9

  • 1高怡,郑劲平.肺功能检查的感染预防与控制[J].中华结核和呼吸杂志,2005,28(7):486-488. 被引量:19
  • 2Visser FJ, Ramlal S, Pelzer B, et al. Random variation of inspiratory lung function parameters in patients with COPD: a diagnostic accuracy study. BMC Pulm Med, 2010,10 : 28.
  • 3Tauhe C, Kanniess F, Gr6nke L, et al. Reproducibility of forced inspiratory and expiratory volumes after bronchodilation in patients with COPD or asthma. Respir Med,2003,97:568-577.
  • 4Ztihlke IE, Kanniess F, Richter K, et al. Montelukast attenuates the airway response to hypertonic saline in moderate-to-severe COPD. Eur Respir J, 2003,22 .. 926-930.
  • 5Leitersdorfer S, Lichtenberger G, Kovacs L Assessment of the results of glottis-dilating operations using lung function tests. Eur Arch Otorhinolaryngol, 2002,259 : 57-59.
  • 6Eikermann M, Groeben H, Hi]sing J, et al. Accelerometry of adductor pollicis muscle predicts recovery of respiratory function from neuromuscular blockade. Anesthesiology, 2003,98 : 1333-1337.
  • 7Ciscar MA, Juan G, Martinez V, et al. Magnetic resonance imaging of the pharynx in OSA patients and healthy subjects. Eur Respir J, 2001,17 : 79-86.
  • 8田艳松,曹洁,朱宝玉,郑立文,王娟,张静,马辉.阻塞性睡眠呼吸暂停综合征患者吸气肺功能及口腔阻断压的变化[J].现代中西医结合杂志,2006,15(23):3176-3178. 被引量:2
  • 9曹洁,陈宝元,郭美南,董丽霞,李玲艳,王彦,朱宝玉.阻塞性睡眠呼吸暂停综合征患者清醒时吸气肺功能变化[J].天津医药,2000,28(10):621-622. 被引量:4

二级参考文献37

  • 1赵向一,黄席珍,周玉淑,刘雪梅,吴全有.经鼻持续性气道正压对阻塞性睡眠呼吸暂停综合征患者呼吸中枢驱动性的影响[J].中华内科杂志,1995,34(12):808-811. 被引量:7
  • 2朱宝玉,陈光瑾,郭仓,杜文彬.肺功能参数自动分析方法及临床应用[J].中国危重病急救医学,1997,9(4):243-245. 被引量:5
  • 3Global Initiative for Asthma(GINA),National Heart,Lung,and Blood Institute. Global Strategy for Asthma Management and Prevention,WHO/NHLBI Workshop Report. National Institutes of Health,Bethesda,2002. Publication No. 02-3659.
  • 4Pauwels RA,Buist AS,Calverley PM,et al. Global strategy for the diagnosis,management,and prevention of chronic obstructive pulmonary disease. NHLBI/WHO Global Initiative for Chronic Obstructive Lung Disease (GOLD) Workshop summary. Am J Respir Crit Care Med,2001,163:1256-1276.
  • 5Rutala DR,Rutala WA,Weber DJ,et al. Infection risks associated with spirometry. Infect Control Hosp Epidemiol,1991,12:89-92.
  • 6Burgos F,Torres A,Gonzalez J,et al. Bacterial colonization as a potential source of nosocomial respiratory infections in two types of spirometer. Eur Respir J,1996,9:2612-2617.
  • 7Kendrick AH,Johns DP,Leeming JP. Infection control of lung function equipment:a practical approach. Respir Med,2003,97:1163-1179.
  • 8Singh V,Arya A,Mathur US. Bacteriology of spirometer tubing and evaluation of methodology to prevent transmission of infection. J Assoc Physicians India,1993,41:193-194.
  • 9Ayres JG,Whitehead J,Boldy DA,et al. Fungal contamination of mini peak flow meters. Respir Med,1989,83:503-504.
  • 10Johns DP,Ingram C,Booth H,et al. Effect of a microaerosol barrier filter on the measurement of lung function. Chest,1995,107:1045-1048.