摘要
通过试验分析了螺旋纽带装置在150MW火电机组凝汽器应用过程中出现的问题。试验结果表明,循环水水质、异物阻塞、纽带表面结垢、螺旋度降低和磨损是影响其效果发挥的主要原因。通过对这些问题的改进,螺旋纽带技术会具有更广阔的应用前景。
The effects of twisted strip used on 150MW steam turbine condenser were studied.The result shows that the water quality of circulating water,stuff obstruction,strip surface scaling,the helicity of twisted strip reducing and the strip abrasion play the main cause which decreased the cleaning effects of twisted strip.The twisted strip technology has broad application prospects based on the solving of these issues
出处
《电力科技与环保》
2013年第4期60-62,共3页
Electric Power Technology and Environmental Protection
基金
内蒙古电力(集团)有限责任公司2010年第二批科技计划项目
关键词
螺旋纽带
凝汽器
防垢
循环水
twisted strip
condenser
anti-scaling
circulating water