期刊文献+

基于MSP430的可存储式人体皮温测量仪 被引量:3

MSP430 Storage Type Human Body Skin Temperature Measuring Instrument
下载PDF
导出
摘要 为准确掌握临床医疗与医学研究中的人体皮温并进一步进行数据分析,利用热敏电阻测温,通过单片机与上位机之间的串口通信,设计了以MSP430F149单片机为核心处理器、热敏电阻与放大器为测量电路、SMC1602为LCD(Liquid Crystal Display)显示器、单片机内部Flash为存储器的可存储式人体皮温测量仪。数据通过串口通信电路传输到上位机,完成数据的分析与处理。实验结果表明,该测量仪测量精度为0.1℃,存储器空间支持持续测量4天以上的皮温数据,能为临床医疗及医学研究提供更可靠的依据。 In order to improve the clinical medical and in medical research on human skin temperature accurately and further analyze the data, use thermistor for temperature measurement, use the single chip microcomputer to accomplish communication. Design the MSP430F149 MCU (Micro Control Unit) as the core processor. Thermistor and amplifier for measurement circuit. SMC1602 for LCD (Liquid Crystal Display) display. MCU internal Flash for memory storage type can human body skin temperature measuring instrument. The measuring instrument storage data through serial communication circuit transmission to epistatic machine. Complete data analysis and processing. The experiment showed that this measuring instrument measuring accuracy is 0.1 ~C. Memory space support continuous measuring four days above the skin temperature data. For clinical medical and medical research provide more reliable basis.
出处 《吉林大学学报(信息科学版)》 CAS 2013年第3期250-254,共5页 Journal of Jilin University(Information Science Edition)
基金 吉林大学创新计划基金资助项目(2011A65122)
关键词 热敏电阻测温 人体皮温测量 分析助诊 MSP430单片机 thermistor temperature measurement human body skin temperature measurement analysis help diagnosis MSP430 chip
  • 相关文献

参考文献10

二级参考文献49

共引文献305

同被引文献23

  • 1孙志远,李清安,乔彦峰,朱玮.提高红外测温系统测温精度的研究[J].仪器仪表学报,2006,27(z1):67-69. 被引量:26
  • 2王立斌,谢涛嵘,张杰,齐红星,陈树德,乔登江.被测对象温度呈现空间分布时的红外测温偏差研究[J].仪器仪表学报,2006,27(10):1288-1293. 被引量:8
  • 3郭天祥.51单片机C语言教程[M].北京:电子工业出版社,2010:124-167.
  • 4谭浩强.C程序设计[M]4版.北京:清华大学出版社,2010.
  • 5求是科技.8051系列单片机C程序设计[M].北京.人民邮电出版社,2006.
  • 6David Ramey DVM, Kristin Bachmann, Martin L. Lee PhD, CStat. A Comparative Study of Non- contact Infrared and Digital Rectal Thermometer Measurements of Body Temperature in the Horse [J]. Journal of Equine Veterinary Science, 2011, 31 (4) :191-193.
  • 7Sarun Sumriddetchkajorn, Kosom Chaitavon. Field test studies of our infrared-based human temperature screening system embedded with a parallel measurement approach [ J ]. Infrared Physics Technology, 2009, 52(4) :119-123.
  • 8SURABHI V, SPINELLO D,NECSULESCU D. Infrared fever body identification using shape and temperature filters [ C ]. 2012 IEEE I2MTC - International Technology Instrumentation and Measurement Conference, Proceedings, 2012 :1556-1560.
  • 9LAHIRI B B, BAGAVATHIAPPAN S, JAYAKUMAR T,et al. Medical applications of infrared thermography: A review[J].Infrared Physics & Technology, 2012, 55(4) : 221-235.
  • 10Filipovic N,Stojanovic R, Lekic N, et al. Monitoring and analysis of vital physiological parameters using PDA devices [ C ]// Radioelektronika (RADIOELEKTRONIKA) ,2014 24th International Conference. Bratislava:IEEE,2014:1 -4.

引证文献3

二级引证文献33

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部