期刊文献+

浅谈纳米材料修饰电极电化学方法检测环境污染物 被引量:3

Electrochemical Determination of Environmental Pollutants based on the Nanomaterials Modified Electrode: A Review
下载PDF
导出
摘要 综述了化学修饰电极以及近几年在环境分析中的应用.首先介绍了化学修饰电极以及它们的类型、制备、应用研究;其次针对纳米材料作为修饰材料进行了简单的介绍以及纳米材料修饰电极环境污染物检测中的应用;最后对近年来采用纳米材料修饰电极电化学及电化学发光分析研究方面的进展及成果进行了汇总、分类以及简单的总结. The paper reviewed the chemically modified electrodes(CMEs) and its application in environmental analysis in the recent years.First,a brief introduction was given about the CMEs with their classification,preparation and application.Then,a simple introduction was given about the nanomaterials and its application in the detection of the environmental pollutants.Finally,authors collected,classified and gave a brief introduction to the recent progress in electroanalytical chemistry and electrogenerated chemiluminescence using nanomaterials modified electrodes.
作者 楚琳 张晓丽
出处 《曲阜师范大学学报(自然科学版)》 CAS 2013年第3期68-72,共5页 Journal of Qufu Normal University(Natural Science)
关键词 电化学 纳米材料 化学修饰电极 electrochemistry nanomaterial chemically modified electrodes
  • 相关文献

参考文献34

  • 1陈莆华,黄国兰,王菊先,等.环境化学[M].天津:南开大学出版社,1993.
  • 2Yamauchi Y, Ido M, Maeda H. High performance liquid chromatography equipped with a cathodic detector and col- umn-switching device as a high-throughput method for a phosphatase assay with p-nitrophenyl phosphate [ J ]. Chem Pharm Bull, 2004, 52:552-555.
  • 3Bravo R, Caltabiano L M, Fernandez C,et al. Quantifica- tion of phenolic metabolites of environmental chemicals in human urine using gas chromatography-tandem mass spec- trometry and isotope dilution quantification [ J ]. J Chroma- togr B,2005, 820:229-236.
  • 4Shkumbatiuk R,Bazel Y R,Andruch V, et al. Investigation of 2-[ ( E ) -2-( 4-diethylaminophenyl ) -I -ethenyl 1-1,3, 3- trimethyl-3H-indolium chloride as a new highly sensitive reagent for the spectrophotometric determination of nitro- phenols[ J ]. Anal Bioanal Chem ,2005,382 : 1431-1437.
  • 5Fa'" hnrich K A, Pravda M,Guilbauh G G. Recent applica- tions of electrogenerated chemiluminescence in chemical a- nalysis [ J ]. Talanta ,2001,54:531-559.
  • 6Richter M M. Electrochemiluminescence (ECL) [ J]. Chem Rev, 2004,104 : 3003-3036.
  • 7Miao W J. Electrogenerated Chemiluminescence and Its Biorelated Applications [ J ]. Chem Rev, 2008,108 : 2506- 2553.
  • 8Hu L Z, Xu G B. Applications and trends in electrochem- iluminescence[ J ]. Chem Soc Rev ,2010,39:3275-3304.
  • 9Xu H,Zhang X L,Zhan J H. Determination of Pentachlo- rophenol at Carbon Nanotubes Modified Electrode Incor-porated with 13-Cyclodextrin [ J ]. J Nanosci Nanoteehnol, 2010, 10:7654-7657.
  • 10Chu L, Han L, Zhang X L. Electrochemical simultaneous determination of nitrophenol isomers at nano-gold modified glassy carbon electrode [ J ]. J Appl Electrochem, 2011, 41:687-694.

同被引文献11

引证文献3

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部