某校区项目施工中采取多项措施控制弱膨胀土回填土含水率,达到控制最低膨胀率的目的,同时通过设置合理的柔性基础垫层,可控制膨胀土回填对建筑物的危害,从而解决了膨胀土不能作为回填土的问题,为全国超过10万km2以上的膨胀土地区地基基础施工带来了可借鉴的成功实例。
A project uses lots of measures to control the moisture of weak expansive soil backfill in a campus,reaches the purpose of minimum expansion .In the meanwhile, through the flexible base cushion is set reasonably,it can control expansion soil backfill on buildings of against,to solve the problem of expansion soil cannot as backfill soil .For national over 100,000 kin2 above of expansion soil area brings has can reference of success instance.