期刊文献+

双液体变焦透镜像差的测量研究 被引量:3

Aberration measurement of double-liquid variable-focus lens
下载PDF
导出
摘要 近几年,双液体变焦透镜在其结构、变焦性能和实际应用中已有了长足的发展,国内也开始自主研发设计双液体变焦透镜。在测量法国Varioptic公司的双液体变焦透镜样品焦距的基础上,利用ZYGO干涉仪以及设计相关的光路,测定了透镜样品的像差,了解样品的像差特性。根据实验可得,Arctic 320型双液体变焦透镜在0V、20V、50V和60V时的Zernike多项式系数较小,残余均方根(root mean square,RMS)反应出整个变焦透镜初级像差较小,成像效果较好,为我国研究双液体变焦透镜提供参考和比较。 In recent years, double-liquid variable-focus lens has achieved so considerable development in terms of its structure, zoom performance and practical application. Similar study, development and design have also been carried in China independently. On the basis of measuring the focal length of the double-liquid variable-focus lens sample of Varioptic Company in France, ZYGO interferometer is used, optical paths is designed, and the aberration of the lens sample is also determined. According to the experiment, it is found that the multinomial coefficient Zernike of Arctic 320 double-liquid variable-focus lens is relatively small at 0 V, 20 V, 50 V and 60 V. Root Mean Square (RMS) reflects that the primary aberration of the whole variable-focus lens is not obvious and the effect of imaging is favorable, which provides references and comparison for domestic studies on double-liquid variable-focus lens.
出处 《光学仪器》 2013年第4期38-42,共5页 Optical Instruments
关键词 液体透镜 像差 干涉仪 liquid lens aberration interferometer
  • 相关文献

参考文献5

二级参考文献49

  • 1康明,岳瑞峰,吴建刚,欧阳帆,刘理天.基于EWOD的锥形管状结构液体变焦透镜[J].传感技术学报,2006,19(05A):1768-1770. 被引量:11
  • 2祝澄,彭润玲,陈家璧.基于电湿效应的双液体透镜[J].大学物理,2007,26(6):57-62. 被引量:9
  • 3BERGE B,PESEUX J.Variable focal lens controlled by an external voltage:an application of electrowetting[J].Eur Phys J E,2000(3):159-163.
  • 4SAUREI L,MATHIEU C,BERGE B.Design of an autofocus lens for VGA 1/4″ CCD and CMOS sensors[J].SPIE,2004,5249:288-296.
  • 5KUIPER S,HENDRIKS B.Liquid lenses provide quality images for camera phones[J].SPIE′s Oemagazine,2005(1):20-23.
  • 6KUIPER S,HENDRIKS B,HUIJBREGTS L J,et al.Variable-focus liquid lens for portable applications[J].SPIE,2004,5523:100-109.
  • 7HOGAN H.Trough a lens,wetly[J].Photonics Spectra,2008(6):86-90.
  • 8PRINS M W J,WELTERS W J J,WEEKAMP J W.Fluid control in multichannel structures by electrocapillary pressure[J].Science,2001,291:277-280.
  • 9HOGAN H.Variable-focus liquid lens relies on fluid pressure[J].Photonics Spectra,2006(4):18-19.
  • 10ROSE M.Liquid lens:water+soung=fast focusing[J].Photonics Spectra,2008(12):26-28.

共引文献22

同被引文献17

引证文献3

二级引证文献14

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部