期刊文献+

光电容积描记技术原理及其应用 被引量:30

Principles of Photoplethysmography and Its Applications in Physiological Measurements
原文传递
导出
摘要 光电容积描记法(PPG)有效利用了光电技术的最新发展及应用成果,借助光电手段,通过检测生物组织血液容积的变化来获得人体生理学信号及特征。它是一种非侵入式测量技术,可广泛用于个人、家庭及大规模人群的生理健康检测和监测。近年来,对PPG及其应用的研究已经成为生物医学工程领域研究的热点问题之一。本文探讨了PPG的光学原理和技术特征,并对其在生理学监测中的应用以及未来发展进行了系统的综述。 The electro-optic technique of measuring the cardiovascular pulse wave, known as photoplethysmography (PPG), is clinically utilised for noninvasive characterisation of physiological components by dynamic monitoring of tissue optical absorption. Non-invasive PPG technology has been used in a wide range of individual, home or public health monitoring. The application of PPG has become one of the hot topics in the fields of biomedical engineering recently. This paper reviews the optical origins of PPG signal, the feature of PPG technology, the applications of PPG in physiological measurements and its development in the future.
作者 石萍 喻洪流
出处 《生物医学工程学杂志》 EI CAS CSCD 北大核心 2013年第4期899-904,共6页 Journal of Biomedical Engineering
关键词 光电容积描记法 朗伯-比尔定律 生理信号检测 Photoplethysmography(PPG) Lamber-Beer's Law Physiological signal detection
  • 相关文献

参考文献29

  • 1AOYAGI T, FUSE M, KOBAYASHI N, et al. Multiwave- length pulse oximetry: theory for the future [J]. Anesth Analg, 2007, 105(6 Suppl): S53-S58.
  • 2WIERINGA F P, MASTIK F, VAN DER STEEN A F. Contactless multiple wavelength photoplethysmographic ima- ging: a first step toward "SpO2 camera" technology[J]. Ann Biomed Eng, 2005, 33(8) : 1034-1041.
  • 3SUN Y, PAPIN C, AZORIN-PERIS V, et al. Use of ambi- ent light in remote photoplethysmographic systems., compari- son between a high-performance camera and a low-cost web- cam[J]. J Biomed Opt, 2012, 17(3) :037005.
  • 4NONNENMACHER A, HOPP H, DUDENHAUSEN J. Predictive value of pulse oximetry for the development of fetal acidosis[J]. J Perinat Med, 2010, 38(1): 83-86.
  • 5EWER A K, MIDDLETON L J, FURMSTON A T, et al. Pulse oximetry screening for congenital heart defects in new- born infants (PulseOx) : a test accuracy study[J]. Lancet, 2011, 378(9793) : 785-794.
  • 6WAGNER J L, RUSKIN K J. Pulse oximetry: basic princi- ples and applications in aerospace medicine[J]. Aviat Space Environ Med, 2007, 78(10): 973-978.
  • 7CHUNG F, LIAO P, ELSAID H, et al. Oxygen desatura- tion index from nocturnal oximetry: a sensitive and specific tool to detect sleep-disordered breathing in surgical patients [J]. Anesth Analg, 2012, .114(5) : 993-1000.
  • 8YAN Y S, POON C C, ZHANG Y T. Reduction of motion artifact in pulse oximetry by smoothed pseudo Wigner-Ville distribution[J]. J Neuroeng Rehabil, 2005, 2(1): 3.
  • 9FOO J Y, WILSON S J. A computational system to optimise noise rejection in photoplethysmography signals during motion or poor perfusion states[J]. Med Biol Eng Comput, 2006, 44 (1-2) : 140-145.
  • 10CHEMLA D, TEBOUL J L, RICHARD C. Noninvasive as- sessment of arterial pressure[J]. Curr Opin Crit Care, 2008, 14(3) : 317-321.

同被引文献164

引证文献30

二级引证文献116

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部