期刊文献+

新型球帽固位体的研究及临床应用 被引量:9

The study and application of the new ball-cap retainers in clinic.
下载PDF
导出
摘要 目的 :简化现有的球帽固位体、降低成本 ,研制开发符合我国国情的球帽固位体 ,并初步应用于临床。方法 :设计了两种球帽固位体 :一种基台与球体为一整体 (A -球 ) ,另一种基台与球体分离 (B -球 )。固位帽由永久软衬直接衬于义齿组织面构成。观察了边缘适合性 ,测量了固位力 ,同时进行了初步临床应用观察。结果 :这两种设计各具特点 ,但A -球结构简单 ,边缘适合性和内部稳定性均好 ,固位力虽不大 ,但患者满意。B -球则相反。固位帽制作方便 ,结构简单 ,与义齿结合牢固。结论 :A -球设计较具临床应用价值。固位帽的设计简单而合理 ,临床初步应用效果良好。 Objective:To simplify the popular ball-cap retainers and to decrease the costs of them. Two new ball-cap retainers were manufactured and applied in clinic. Methods:One was A-ball whose abutment cooperated in the ball attachment, the other one was B-ball whose abutment separated from the ball attachment. The cap was made of permanent soft-liner in the denture base. The marginal fits were observed. And the retentive forces were measured. Then the retainers were used in clinic. Results:The characteristics of these two retainers were different. A-ball was simple in structure and easy to be manufactured. It had a better marginal fitness and stability. Its retentive force was not too big, but satisfied by patients. B-ball was on the contrary with A-ball. Conclusion: A-ball was more practical in clinic. The design of the cap was simple and reasonable. And its pilot use effect was good in clinic. [
出处 《口腔医学纵横》 CSCD 2000年第4期243-246,共4页 Journal of Comprehensive Stomatology
关键词 球帽固位体 设计 性能 研究 临床应用 义齿 修复 ball-cap retainer design properties application
  • 相关文献

参考文献11

  • 1[1] Cohen BI,Pagnillo M,Condos S,et al. Comparative study of two precision overdenture attachment designs[J]. J Prosthet Dent, 1996, 76(2)∶145-152
  • 2[2] Lill W,Matejka M,Rambousek K et al. The ability of currently available stress-breaking elements for osseointegrated implants to imitate natural tooth mobility[J]. Int J Oral Maxillofac Implants, 1988, 3∶281-286
  • 3[3] Davis DM,Rimrott R,Zarb GA. Studies on frameworks for osseointegrated prostheses: Part2. The effect of adding acrylic resin or porcelain to from the occlusal superstructure[J]. Int J Oral Maxillofac Implants, 1988, 3∶275-280
  • 4[4] Chapman RJ, Kirsch A. Variations in occlusal forces with a resilient internal implant shock absorber[J]. Int J Oral Maxillofac Implants, 1990, 5∶369-374
  • 5[5] Wang yi-ning, Per-olof Glantz, Krister Ninler. Biomechanical influence of the different attachments on implant-retained overdentures[J]. 口腔医学纵横杂志,1999,15(3)∶174-179
  • 6[6] Yoeli Z, Miller V, Zaltser Ch. Consistency and softness of soft liners[J]. J Prosthet Dent, 1996,75∶412-418
  • 7[7] Emmer ThJ.Jr, Emmer ThJ.Sr, Vaidynathan J, et al. Bond strength of permanent soft denture liners bonded to the denture base[J]. J Prothet Dent, 1995, 74∶595-601
  • 8[8] Wagner WC, Kawano F, Dootz ER, Koran A. Dynamic viscoelastic properties of processed soft denture liners; Part Ⅱ-Effect of aging[J]. J Prosthet Dent, 1995, 74∶299-304
  • 9[9] Cain JR, Mitchell DL. Soft liner-retained, implant-supported overdenture: a technical note[J]. Int J Oral Maxillofac Implants, 1998, 13∶857-860
  • 10王革.种植义齿固位系统内部适合性的研究进展[J].国外医学(口腔医学分册),1998,25(6):332-335. 被引量:6

共引文献13

同被引文献43

引证文献9

二级引证文献44

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部