以某电厂500 kV系统为例,介绍了RCS-992A分布式安全稳定控制系统的配置、作用及功能,分析了设备的升级改造和调试情况。该装置投运后,提高了电厂的经济效益和电网的安全、稳定性。
Taking the 500 kV system of a power plant as example,the configuration and the functions of the RCS- 992A distributed safety and stabilization control system were introduced.The upgrade reformation and debugging of the equipment were analyzed. After the equipment had been put into operation,the economic benefit of the power plant and the safety and stability of the power grid were improved.
出处
《华电技术》
CAS
2013年第8期46-48,51,共4页
HUADIAN TECHNOLOGY
关键词
水电厂
安全稳定控制系统
切机
改造
经济效益
hydropower plant
safety and stabilization control system
switch off generator
reformation
economic benefit