变频凝结水泵振动问题的分析与处理 被引量:13

Analysis on Vibration of Frequency Conversion Condensate Pump and Disposal Measures
下载PDF
导出
摘要 广东大唐国际潮州发电公司2台1 000 MW机组变频凝结水泵电机自机组试运投产以来,振动严重超标,无法满足生产要求。分析振动原因,判断变频凝结水泵系统存在结构共振,采用电机加固、现场整体动平衡校正等措施后,取得良好效果。 Since being put into operation, vibration of electrical machines of frequency conversion pumps of two 1 000 MW units of Guangdong Datang International Power Generating Company are seriously exceeding standards that can not meet production requirements. This paper analyzes vibration reasons and considers there is a problem of structural resonance of (requency conversion condensate pump system. It suggests to take measures such as reinforcing the electrical machine and correcting field integrated dynamic balance.
作者 黑宗华
出处 《广东电力》 2013年第9期110-112,116,共4页 Guangdong Electric Power
关键词 共振 故障诊断 加固 动平衡 resonance fault diagnosis reinforce dynamic balance