摘要 目的:探讨大孔径16排螺旋CT在放疗模拟定位中的应用。方法:应用大孔径16排螺旋CT进行乳腺癌保乳术后根治性放疗乳腺切线野的CT模拟定位,并对CT模拟定位技术与传统X射线模拟定位技术进行比较,同时与单排螺旋CT的图像进行比较。结果:大孔径16排螺旋CT在放疗模拟定位中的应用避免了因患者体位受限而造成的误差;大孔径16排螺旋CT模拟机的定位验证误差均优于传统X射线模拟机;其图像质量优于单排螺旋CT。结论:大孔径16排螺旋CT模拟定位机的应用,使得放疗定位更加精确,计划和治疗更加准确。 Objective: To discuss application of large aperture 16 row spiral CT in radiotherapy simulation positioning. Methods: To apply CT simulation positioning with large aperture 16 row spiral CT for the breast tangential field by early breast cancer after breast conserving surgery and radical radiotherapy. Compare CT-simulation and X-ray conventional positioning technique and Compare large aperture 16 row spiral CT and single row spiral CT image. Results: The application of large aperture 16 row spiral CT avoided the error because of body limited. Large aperture 16 row spiral CT simulation position validation error is superior to X-ray positioning. Its image quality is better than that of single row spiral CT. Conclusion: The application of large aperture 16 row spiral CT make simulation positioning more accurate, planned and treatment more accurate, it can pr.ovide.guarantee of accurate simulation position!ng !or.accurate. plan and treatment.
出处 《中国医学装备》 2013年第10期16-18,共3页 China Medical Equipment
关键词 大孔径16排螺旋CT 模拟定位 放射治疗 Large aperture 16 row spiral CT Simulation positioning IRradiation therapy
  • 相关文献

参考文献16

  • 1李宝生,罗立民,于金明,卢洁,李文武,徐本华.乳腺保留术后CT虚拟模拟定位技术[J].中华放射肿瘤学杂志,2002,11(2):103-104. 被引量:6
  • 2Ragan DP,He T,Mesina CF,et al. CT-based simulation with laser patient marking[J].Med phys, 1993,20(2pt 1):379-380.
  • 3吴钦宏,李雪南,刘春玲,朱宝全,田丽红,张清文,竺萌,秋晞,王婵,李高峰.应用锥形束CT评价最终等中心标记法定位头颈部肿瘤的摆位误差[J].中华放射医学与防护杂志,2012,32(3):301-303. 被引量:3
  • 4Clarke M,Collins R,Darby S,et al.Effects ofradiotherapy and of differences in the extent of surgery for early breast cancer on local recurrence and 15-year survival: an overview of the randomized trials[J]. Lancet, 2005,366(14) .. 2087-2106.
  • 5Lingos TI,Recht A,Vicini F,et al.Radiation pneumonitis in breast cancer patients treated with coaservative surgery and radiation therapy[J].Int J Radiat Oncol Biol Phys,1991, 21(2): 355-360.
  • 6Potters L,Steinberg M,Wallner P,et al. How one defines intensity-modulated radiation therapy[J].Int J Radiat Oncol Biol Phys,2003, 56(4): 609-610.
  • 7Glatstein E.The return of the snake oil salesmen[J].Int J Radiat Oncol Biol Phys,2003, 55(3):561-562.
  • 8Arriagada R,I MG,Rochard F,et al.Conservative treatment versus mastectomy in early breast cancer:Patterns of failure with 15 years of follow-up data[J]. J Clin Oncol, 1996,14(2): 1558-1564.
  • 9Veronesi U,Cascinelli N,Mariani L,et al.Twenty-year follow-up of a randomized study comparing breast-conserving surgery with radical mastectomy for early breast cancer[J].N Engl J Med, 2002,347(16). 1227-1232.
  • 10Fisher B,Anderson S,Bryant J,et al.Twenty- year follow-up of a randomized trial comparing total mastectomy, lumpectomy,and lumpectomy plus irradiation for the treatment of invasive breast cancer[J].N Engl J Meal,2002,347(16): 1233-1241.

二级参考文献32

  • 1周丹.医院医疗设备质控体系的建立和实施[J].中国数字医学,2007,2(8):18-21. 被引量:83
  • 2阮兴云,张良才,朱弋,李晓东.医疗设备质量控制管理模式探索与设想[J].中国医学装备,2007,4(7):17-19. 被引量:17
  • 3McCullough EC,Payne JT,Baker HL,et al.Performance evaluation and quality assurance of computed tomography scanners with illustrations from the EMI,ACTA,and delta scanners[J].Radiology,1976,120:173-188.
  • 4White DR,Speller RD,Taylor PM.Evaluating performance characteristics in computerized tomography[J].Br J Radiol,1981,54:221-231.
  • 5AAPM Report No.39,Specification and acceptance testing of computed tomography scanners[J] American Institute of Physics,1993.
  • 6AAPM Report No.74,Quality control in diagnostic radiology,Medical Physics Publishing,2002.
  • 7大型医用设备配置与应用管理暂行办法-卫生部令第43号,1995,7.
  • 8X射线计算机体层摄影装置(CT)应用质量检测与评审规范-全国大型医用设备应用技术评审委员会编,1997.
  • 9Mutic S,Palta JR,Butker EK. Quality assurance for computed-tomography simulators and the computed-tomography-simulation process:report of the AAPM Radiation Therapy Committee Task Group No.66[J].Mad Phys,2003,(10):2762-2792.
  • 10van Herk M,Remeijer P,Rasch C. The probability of correct target dosage:dose-population histograms for deriving treatment margins in radiotherapy[J].International Journal of Radiation Oncology,Biology,Physics,2000,(04):1121-1135.

共引文献71

同被引文献52

  • 1张怀文,王运来,戴相昆,鞠忠建.影像引导放疗中常用CT设备影像质量的比较分析[J].中国医学物理学杂志,2011,28(2):2523-2528. 被引量:8
  • 2Bauman G,Yartsev S,Coad T,et al. Helical tomotherapy for craniospinal radiation[J].Br J Radiol, 2005,78(930). 548-552.
  • 3Sterzing F,Schubert K,Sroka-Perez G,et al.HeEcal tomotherapy--Experience of the first 150 patients in Heidelberg[J].Strahlenther Onkol, 2008, 184(1):8-14.
  • 4Langen KM,Zhang Y,Andrews RD,et al.Initial experience with megavoltage(MV)CT guid-ance daily prostate alignments[J].int J Radiat Oncoi Biol Phys, 2006,66(3): 876-882.
  • 5Amish P,Katja M,Kenneth J,et al. Patient close from megavoltage computed tomography imaging[J].Int J Radiat Oncol Biol Phys, 2008,70(5) : 1579-1587.
  • 6Li B,Lu H,Luo LM,et al.Novel technique for craniospinal radiotherapy with patient supine[J].J Southeast University(English Edition),2009,25(3): 326-329.
  • 7Yoon M,Shin DH,Kim J,et al. Craniospinal irradiation techniques:a dosimetric comparison of proton beams with standard and advanced Dhoton radiotherapy[J].Int J Radiat Oncol Biol P hys, 2011,81(3): 637-646.
  • 8Sharma DS,Gupta T,Jalali R,et al. High- precision radiotherapy for craniospinal irradiation:evaluation of three-dimensional conformal radiotherapy, intensity-modulated radiation therapy and helical tomotherapy[J].Br J Radiol, 2009,82(984): 1000-1009.
  • 9Park W,Brodeur M,Roberge D,et al.Standard and nonstandard craniospinal radiaotherapy using helical tomotherapy[J].Int J Radiat Oncol Biol Phys, 2010,77(3): 926-931.
  • 10Penagaricano J, Moros E, Coppy P,et al.Pediatric craniospinal axis irradiation with helical tomotherapy:patient outcome and lack of acute pulmonary toxicity[J].Int J Radiat Oncoi Biol Phys, 2009,75(4) : 1155-1161.

引证文献6

二级引证文献27

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部