摘要 目的应用静电纺丝法制备一种双层蛛丝蛋白血管支架,观察血管支架的微观结构,并研究其生物力学性能和细胞相容性。方法配制纺丝液,通过静电纺丝,以旋转接收棒为收集装置,制备(pNSR16/PCL/CS)/(pNSR16/PCL/Gt)双层蛛丝蛋白血管支架。探讨质量分数和管壁厚度对血管支架孔隙率、爆破强度、拉伸性能、缝合强度和水渗透性的影响,并检测血管支架的细胞毒性和细胞黏附性能。结果血管支架的微观结构为纤维随机分布的三维多孔网状,爆破强度、拉伸强度和缝合强度大小均与支架的质量分数和管壁厚度成正比,孔隙率、水渗透性和断裂伸长率大小与支架的质量分数和管壁厚度成反比。血管支架爆破强度的范围为43~150 kPa,高于生理血压;缝合强度高于0.19 N,符合体内移植要求;拉伸强度高于人体桡动脉血管,满足体内移植的要求;水渗透性为0.3~0.6 mL·min-1·cm-2。血管支架无细胞毒性,有利于内皮细胞细胞黏附及增殖。结论使用静电纺丝法制备双层蛛丝蛋白血管支架是可行的,其优异的生物力学性能和生物相容性能表明其能应用于体外组织工程血管的构建,具有进一步应用于血管移植物研究的前景,为临床应用奠定了一定的基础。 Objective To prepare a bilayer spider silk protein vascular scaffold using electrospinning, observe mi- crostructure of the vascular scaffold and study its biomechanical properties and cell compatibility. Methods Spin- ning solution was electrospun to prepare (pNSRI6/PCL/CS)/(pNSR16/PCL/Gt) bilayer spider silk protein vas- cular scaffold using rotating receiving rod as the collection device. The effects of mass fraction and wall thickness on the porosity, bursting strength, tensile properties, suture retention strength and water permeability of the vas- cular scaffold were investigated, and cytotoxicity and cell adhesion property of the vascular scaffold were tested. Results The vascular scaffold presented three-dimensional porous microstructure with randomly distributed fi- bers. The bursting strength, tensile strength and suture retention strength were directly proportional to mass frac- tion and wall thickness, but the porosity, water permeability and elongation at break were inversely proportional to mass fraction and wall thickness. The bursting strength range of vascular scaffold was 43 - 150 kPa, which was higher than the physiological blood pressure; the suture strength was above 0.19 N, which was consistent with the transplantation requirement in vivo; the tensile strength was higher than that of human radial artery, which met the transplantation requirement in vivo; the range of water permeability was 0.3 - 0.6 mL · min 1· cm-2 The vascular scaffold had no cytotoxicity and facilitated the adhesion and proliferation of endothelial cells. Conclu-sions It is feasible to prepare the bilayer spider silk protein vascular scaffold through electrospinning. The superi- or biomechanical properties and biocompatibility properties show that the bilayer spider silk protein vascular can be used for construction of the tissue engineered blood vessels in vitro, with prospect for further vascular graft study, which lays a foundation for its clinical application.
出处 《医用生物力学》 EI CAS CSCD 北大核心 2013年第5期559-566,共8页 Journal of Medical Biomechanics
基金 福建省科技厅重点项目(2010Y0020) 国家级大学生创新创业训练计划(201210394016)
关键词 双层蛛丝蛋白血管支架 生物力学特性 细胞相容性 静电纺丝 组织工程 Bilayer spider silk protein vascular scaffold Biomechanical properties Cell compatibility Electrospin-ning Tissue engineering
  • 相关文献

参考文献21

  • 1Lynda V, Thomas U, Arun S, et al. A biodegradable and biocompatible PVA-citric acid polyesterwith potential appli- cations as matrix for vascular tissueengineering [ J ]. J Ma- ter Sci Mater Med, 2009, 20( Suppl t ) : S259-269.
  • 2Jeffrey TK, David AV. Adult stem cell-based tissue engi- neered blood vessels.. A review [ J ]. Biomaterials, 2012, 33(12) : 3388-400.
  • 3Wang XN, Chen CZ, Yang M, et aL Implantation of decel- lularized small-calibervascular xenografts with and without surface heparin treatment [ J]. Artif Organs, 2007, 31 (2) .. 99-104.
  • 4Grassl ED, Oegema TR, TranquUlo RT. A fibrin-based ar- terial media equivalent [ J]. J Biomed Mater Res A, 2003, 66(3) : 550-561.
  • 5Seliktar D, Nerem RM, Galls ZS. Mechanical strain-stimu-lated remodeling of tissue-engineered blood vessel con- structs [J],Tissue Eng, 2003, 9(4) : 65?-666.
  • 6Nieponice A, Soletti L, Guan J, et aL Development of a tissue-engineered vascular graft combining a biodegradable scaffold, muscle-derived stem cells and a rotational vacu- um seeding technique[J]. Biomaterials, 2008, 29 ( 7 ) : 825 -833..
  • 7Niklason LE, Gao J, Abbott WM, et al. Functional arteries grown in vitro [J]. Science, ]999,284(54]3) : 489-493.
  • 8LHeureux N, Dusserre N, Konig G, et al. Human tissue- engineered blood vessels for adult arterial revascularization [J]. Nat Med, 2006, ]2(3) : 36]-36.5.
  • 9孔翰,张明亮,严志强,姜宗来.高血压与低切应力对大鼠颈总动脉血管重建的影响[J].医用生物力学,2011,26(2):109-115. 被引量:9
  • 10Osnat H, David PK, Fritz V, et al. Spider and mulberry silkworm silks as compatible biomaterials [ J ]. Compos B Eng, 2007, 38(3) : 324-337.

二级参考文献193

共引文献62

同被引文献29

  • 1高峰,胡平,周建业,高峰,孟亮,胡盛寿.组织工程补片修补犬腹主动脉的实验研究[J].中华胸心血管外科杂志,2004,20(4):230-233. 被引量:4
  • 2杨杰,黄楠,杜全兴,张勇,陈虬.描述血管支架力学性能的新概念──形状系数[J].生物医学工程学杂志,2006,23(1):74-77. 被引量:10
  • 3Onuma Y, Daemen J, Kukreja N, et al, Revascularization in the high-risk patient: mu|ti'essel disease[]]. Minerva Cardioanglol 2007, 55:579 - 592.
  • 4Basaran O, Karakayali H, Emiroglu R, et al. Complications and long-term follow-up of 4416 vascular access procedures [ J ]. Transplant Proe, 2003, 35:2578 - 2579.
  • 5Allmeling C, Jokuszies A, Reimers K, et al. Spider silk fibres in artificial nerve constructs promote peripheral nerve regeneration [J]. Cell Prolif, 2008, 41 (3) : 408 -420.
  • 6Wang Hongxin, Xue Zhengxiang, Wei Meihong, et al. A novel scaffold from recombinant spider silk protein in tissue engineering [ J ]. Advanced Materials Research, 2011, 152 - 153 : 1734 - 1744.
  • 7Xiang Ping, Li Min, Zhang Chaoying, et al. Cytocompatibility of electrospun recombinant spider silk protein/polycaprolactone/ gelation composite tubular scaffolds for small diameter tissue engineering blood vessels [ J]. Int J Biol Macromol, 2011, 49 (3) : 281 -288.
  • 8Zhao Liang, Chen Denglong, Wei Meihong, et al. Preparation of a recombinant spider silk protein/pcl blend submicrofibrnus mat and cytocompatibility [ J ]. Polymers & Polymer Composites, 2013, 21(2) :61 -68.
  • 9Meng J, Kong H, Han Z, et al. Enhancement of nanofibrous scaffold of muhiwalled carbon nanotubes/polyurethane composite to the fibroblasts growth and biosynthesis [ J]. J Biomed Mater ResA, 2009, 88(1) :105 - 116.
  • 10Rayatpisheha S, Heathb DE, Shakouric A, et al. Combining cell sheet technology and electrospun scaffolding forengineered tubular, aligned, and contractile blood vessels [ J ]. Biomaterials, 2014, 35(9): 2713-2719.

引证文献3

二级引证文献9

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部