期刊文献+

4D CT图像的肺部呼吸运动估计 被引量:3

Estimation of Lung Respiratory Motion Based on 4D CT
下载PDF
导出
摘要 四维计算机断层扫描(Four-dimensional computed tomography,4D CT)通过对病人多个呼吸周期进行连续扫描,可以提供肺部全方位的动态信息,对肺部肿瘤的诊断、跟踪和放疗具有重要的作用。本文提出了一种基于B样条形变模型的四维图像配准算法对病人肺部的呼吸运动进行估计。为了充分利用4D CT的时间连贯性信息,保证4D CT配准的稳定性,定义了一个新的图像相似性测度函数,并采用迭代的方法对变形场进行优化求解。实验中,通过和成对三维B样条配准算法进行对比来验证本文算法性能。实验证明:所提的4D CT形变配准算法更加精确和稳定,配准精度可以达到1.22±0.74mm。最后作为应用,对7位病人吸气末相位到呼气末相位的呼吸运动进行估计,并给出了统计结果。 Four-dimensional computed tomography (4D-CT) has been developed as a new imaging technology recently.By scanning the multi-breath cycle of the patient continuously,it can provide full range of lung dynamic information and plays an important role in the diagnosis,tracking and radiotherapy of lung cancer.A B-spline deformable model based registration algorithm is proposed for the accurate estimation of lung respiratory motion using 4D CT data.A new image similarity measure is defined to take advantage of temporal coherence information of 4D CT and guarantee the stability of registration.Meanwhile,the deformation field between end-inhale phase CT and other respiratory phase CT is refined by an iterative way.The registration algorithm is evaluated by comparing with pairwise 3D B-spline based registration algorithm according to simulated ground-truth deformation field.The results demonstrate that the proposed algorithm is more accurate and stable,and it can yield a registration error of 1.22±0.74 mm.Finally,the algorithm is applied to 4D CT data of seven patients to estimate the lung respiratory motion between end-inhale and end-exhale phases.
出处 《数据采集与处理》 CSCD 北大核心 2013年第5期608-613,共6页 Journal of Data Acquisition and Processing
关键词 图像形变配准 呼吸运动 时间连贯性 三维渲染 4D CT deformable image registration respiratory motion temporal coherence 3D rendering 4D CT
  • 相关文献

参考文献13

二级参考文献53

共引文献37

同被引文献46

  • 1KEALL P. 4-dimensional computed tomography imaging and treat- ment planning[J]. Seminars in Radiation Oncology, 2004, 14( 1): 81 -90.
  • 2PARTRIDGE M, TREE A, BROCK J, et al. Improvement in tumour control probability with active breathing control and dose es- calation: a modelling study [ J]. Radiotherapy and Oncology, 2009, 91 (3) : 325 - 329.
  • 3WUNDERINK W, MENDEZ-ROMERO A, de KRUIJF W, et al. Reduction of respiratory liver tumor motion by abdominal compres- sion in stereotactic body frame, analyzed by tracking fiducial mark- ers implanted in liver[ J]. International Journal of Radiation Oncolo- gy Biology Physics, 2008, 71(3) : 907-915.
  • 4GIRAUD P, MORYAN E, CLAUDE L, et al. Respiratory gating techniques for optimization of lung cancer radiotherapy [ J]. Journal of Thoracic Oneology, 2011,6(12) : 2058 - 68.
  • 5LI T, SCHREIBMANN E, THORNDYKE B, et al. Radiation dose reduction in four-dimensional computed tomography [ J]. Medical Physics, 2005, 32(12) : 3650 -3660.
  • 6SCHREIBMANN E, CHEN G T Y, XING L. Image interpolation in 4D CT using a B-spline deformable registration model[ J]. Interna- tional Journal of Radiation Oneology Biology Physics, 2006, 64(5) : 1537 - 1550.
  • 7TIAN Z, JIA X, DONG B, et al. Low-dose 4DCT reconstruction via temporal nonloeal means[ J]. Medical Physics, 2011, 38(3) : 1359 - 1365.
  • 8KIM K S, YE J C. Low-dose limited view 4DCT reconstruction u- sing patch-based low rank regularization[ C]// Proceedings of the 2013 IEEE Nuclear Science Symposium and Medical Imaging Con- ferencc. Piscataway: IEEE Press, 2013:1 -4.
  • 9THIRION J P. Image matching as diffusion process: an analogy with Maxwell's demons[ J]. Medical Image Analysis, 1998, 2( 3): 243 - 260.
  • 10WANG H, LEI D, O'DANIEL J. Validation of an accelerated 'de- mons' algorithm for deformable image registration in radiation thera- py [ J]. Physics in Medicine Biology, 2005,50(12) : 2887 - 2905.

引证文献3

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;