离子选择电极法测定饲料中氟的不确定度评定 被引量:3

Uncertainty Evaluation of Determination of Fluorine in Feed Premixes by Ion Selective Electrode Method
下载PDF
导出
摘要 对离子选择电极法测定饲料中氟含量的测量不确定度进行了评定。通过建立测定过程中各分量的数学模型,分析、识别了不确定度来源,其不确定度主要来源于标准溶液、最小二乘法线性拟合曲线、定容体积、试样称量、回收率、重复测定等因素。在对各不确定度分量进行量化的基础上,合成得到了测定结果的相对不确定度。结果表明,重复测定、标准溶液和最小二乘法线性拟合曲线引入的不确定度对总不确定度贡献率最大,是影响该方法不确定度的主要因素,为采用该方法测定饲料中氟含量的质量控制提供了理论依据。 In this paper, the measurement uncertainty for determination of fluorine in feed by ion selective electrode method was evaluated. By researching on mathematical model of each component in the process of measurement, the main sources of uncertainty were analyzed and identified. The main sources of uncertainty in the measure- ment process were the standard solution, and the standard linear fitting curves by the method of least squares ; the total volume of samples test liquid, sample weighing, reference materials, spike recovery and repetitive test. The impact of ev- ery uncertainty component for the measurement uncertainty was estimated. Based on the quantitative analysis of every source, the relative standard uncertainty of measurement result was obtained. The evaluation indicated that major sources of uncertainty were repetitive test, standard solution and standard linear fitting curves by the method of least squares. This evaluation provided a theoretical basis for the quality control of fluorine content determination in feed premixes.
出处 《中国粮油学报》 EI CAS CSCD 北大核心 2013年第11期103-107,共5页 Journal of the Chinese Cereals and Oils Association
基金 四川省2011年科技支撑计划(2011CCZ0005)
关键词 测量不确定度评定 离子选择性电极法 饲料 measurement uncertainty evaluation ion selective electrode method fluorine feed
  • 相关文献

参考文献11

二级参考文献4

  • 1JJG1059-1999.测量不确定度评定与表示[S].北京:中国标准出版社,1999.
  • 2WS/T89-1996.尿中氟化物的测定[S].
  • 3JJF1059-1999.测量不确定度评定与表示[S].[S].,..
  • 4国家环境保护总局<水和废水监测分析方法>编委会.水和废水监测分析方法[M].北京:中国环境科学出版社,2002.

共引文献72

同被引文献26

引证文献3

二级引证文献9

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部