摘要
介绍了9E燃机的点火后熄火跳机逻辑组态,以及上海闸电燃机电厂几起典型9E燃机熄火跳机情况,并对机组熄火跳机的原因进行了分析,提出了相应的处理对策。
This paper introduces the logic configuration of 9E gas turbine flame-out shutdown after ignition, as well as several typical cases in the Shanghai Zhabei Gas Turbine Power Plant. Then the reasons are analyzed and the corre-sponding countermeasures are proposed.
出处
《华东电力》
北大核心
2013年第11期2439-2442,共4页
East China Electric Power
关键词
燃气轮机
熄火跳机
旁路伺服阀
流量分配器
二次滤网
gas turbine
flame-out shutdown
bypass servo valve
flow divider
secondary strainer