期刊文献+

瞬时多光谱爆温测量系统 被引量:5

TRANSIENT MULTI-WAVELENGTH DETONATION TEMPERATURE MEASURING SYSTEM
下载PDF
导出
摘要 本文针对国内外近年来常用的爆炸温度测量方法在原理、结构上的不足 ,提出了一种更符合实际测量要求的瞬时多光谱爆温测量系统 ,阐述了它的基本工作原理 ,给出了总体构成结构 ,并指出了这种新方案不同于以往方法的特点 .利用该系统可在一次爆炸过程的 1 0 0 ns时间内完成四个时刻爆轰温度的测量 ,最后通过阶段实验结果证实了它的可行性 . In thispaperin orderto make up forthe shortness on principleand structure of several det- onation temperature thermometries of lastyears,a new type system,transientmulti-wavelength deto- nation temperature-measuring system,which is more agreeable to practical measuring requirements is introduced.It′s basic measuring principle and structure frame are described and features differentfrom those previous pointed.With this system four time temperatures during1 0 0 ns detonation can be mea- sured,and in the end it s feasibility to measure transientdetonation temperature is made sure though momentexperiment results.
出处 《光子学报》 EI CAS CSCD 2000年第10期937-941,共5页 Acta Photonica Sinica
关键词 爆温测量系统 辐射测温 瞬时多光谱测量 炸药 Detonation temperature Radialization thermometry Channel Transient multi-wavelength measurement
  • 相关文献

参考文献3

  • 1戈古利亚MΦ.凝聚介质的冲击压缩温度[M].中物院流体物理研究所科协,1994.5-21.
  • 2Xianchu H,Proc of Eighth Symposium ( International) on Detonation,1995年,322页
  • 3戈古利亚 M Φ,凝聚介质的冲击压缩温度,1994年,5页

同被引文献80

引证文献5

二级引证文献15