摘要 基于CE-3极紫外(EUV)相机最高工作温度为70 ℃的要求,对EUV相机的微通道板(MCP)位置灵敏阳极光子计数成像探测器实验件在70 ℃时的性能进行了研究,该探测器主要由工作在脉冲计数模式下的MCP堆、楔条形感应电荷阳极及相关的模拟和数据处理电路组成。为了获得稳定的MCP堆电子增益及较小的暗计数率,对MCP堆进行了预处理,包括380 ℃条件下真空高温烘烤18 h,以及电子清刷100 μA·h,并测量了预处理前后暗计数率;测量了探测器工作在室温和70 ℃时的暗计数率、空间分辨率、增益,测量结果表明探测器的空间分辨率为5.66 lp/mm,与室温下空间分辨率相同,暗计数率虽然小于1 counts/(s·cm2),但70 ℃暗计数率是室温的2~5倍;对探测器的使用寿命进行了初步分析。实验结果和分析表明探测器在空间分辨率、暗计数率、使用寿命等方面均满足EUV相机的要求。 A two-dimensional photon-counting imaging detector with induced charge wedge-strip anode in extreme ultraviolet (EUV) region is developed based on the maximal operating temperature of 70 ℃ for CE-3 EUV camera, which will be applied to the characteristic performance test at 70 ℃. The detector is mainly composed of microchannel plate (MCP) stacks operating in pulse-counting mode, wedge-strip position-sensitive anode and correlative analog and data processing circuit. A three-electrode wedge-strip induced-charge position-sensitive anode with 1.5-mm period and 47-mm diameter active area is designed and fabricated, and front-end analog and data circuit with the maximum rate of 200 kHz is also developed. In order to obtain MCP stack′s steady gain and less background noise, the preconditioning of MCP stack including 380 ℃ bake-out for 18 h and 100 μA·h bake-in is done, background rate is measured before and after preconditioning, and the curve of MCP stack′s gain versus high voltage applied to MCP stack is obtained. Operating characteristics of the MCP detector including background rate, spatial resolution are also measured. The life-span of the detector is analyzed. The measured results show that the spatial resolution can reach 5.66 lp/mm, and background noise is less than 1 counts/(s·cm2), they can completely satisfy the requirement of moon-based EUV camera on the spatial resolution, background noise and life-span.
作者 尼启良
出处 《光学学报》 EI CAS CSCD 北大核心 2013年第11期20-24,共5页 Acta Optica Sinica
基金 国家自然科学基金(61077016 61275152) 吉林省科技发展重大项目(20116013)
关键词 探测器 光学器件 光子计数成像探测器 极紫外 微通道板 感应电荷楔条形阳极 detectors optical devices photon-counting imaging detector extreme ultraviolet microchannel plate induced charge wedge-strip anode
  • 相关文献

参考文献10

  • 1O H W Siegmund, M Lampton, S Chakrabarti, et al.. Application of wedge and stripe image readout systems to detectors for astronomy [C]. SHE, 1986, 627 660--665.
  • 2于磊,曲艺,林冠宇,王淑荣.120~180nm星载远紫外电离层成像光谱仪光学系统设计与研究[J].光学学报,2011,31(1):155-161. 被引量:19
  • 3于磊,王淑荣,曲艺,林冠宇,张振铎.用于电离层探测的单光栅高分辨率成像光谱仪光学系统研究[J].光学学报,2011,31(7):127-134. 被引量:7
  • 4S Diebold, J Barnstedt, H-R Elsener, et al.. MCP detector development forWSO-UV[C]. SPIE, 2012, 8443 84432X.
  • 5于磊,林冠宇,于向阳.空间高层大气遥感远紫外成像光谱仪的光学系统[J].光学学报,2013,33(1):180-186. 被引量:14
  • 6B R Sandel, A L Broadfoot, C C Crtis, et al.. The extreme ultraviolet imager investigation for the image mission [J]. Space Sci Rev, 2000, 91(1-2) 197--242.
  • 7M Pfeifer, J Barnstedt, C Bauer, al.. Low-power readout electronics for microchannel plate detectors with cross strip anodes [C]. SHE, 2012, 8443: 844320.
  • 8G W Fraser, J F Pearson, J E Lees. Dark noise in microchannel plate X-ray detectors [J]. Nucl Instrum Meth A, 1987, 254(2): 447--462.
  • 9David J Sahnow. Long term gain variation in the FUSE detectors [C]. SPIE, 2004, 5488: 731--737.
  • 10O H W Siegmund. Preconditioning of microchannel plate stacks [C]. SHE, 1989, 1072: 111--118.

二级参考文献21

  • 1F. W. Schenkel, B. S. Ogorzalek, J. C. Larrabee et al.. Ultraviolet daytime ouroral ionospheric imaging from space[J].Appl. Opt., 1985, 24(20): 3395-3405.
  • 2L. J. Paxton, A. B. Christensen, D.Morrison et al.. hyperspectral imager for geospace[C]. SPIE, 2004, 5660: 228-239.
  • 3Robert P. McCoy, Kenneth F. Dymond, Gilbert G. Fritz et al.. special sensor uitraviolet limb image: anionospheric and neutral density profiler for the defense meteorological satellite program satellites[J].Opt. Engng., 1994, 33(2): 423-429.
  • 4Larry J. Paxton, Ching--I. Meng, Glen H. Fountain et al.. SSUSI Horizon-to-horizon and limb-viewing spectrographic imager for remote sensing of environmental parameters[C]. SPIE, 1993, 1764: 161-175.
  • 5B. Arthur, Shafer, R. Lawrence. Megill, Leann Droppleman. Optimization of the Czerny-Turner spectrometer[J].J. Opt. Soc. Am., 1964, 54(7): 879-887.
  • 6Li Xu, Kexin Chen, Qingsheng He et al.. Design of freeform mirrors in Czerny-Turner spectrometers to suppress astigmatism[J].Appl. Opt., 2009, 48(15): 2871-2879.
  • 7Dane R. Austin, Tobias Witting, lan A. Walmsley. Broadband astigmatism-free Czerny-Turner imaging spectrometer using spherical mirrors[J].Appl. Opt., 2009, 48(19): 3846-3853.
  • 8Daniel Morrison, Larry Paxton, Dave Humm et al.. On-orbit calibration of the special sensor ultraviolet scanning imager (SSUSI) a far-UV imaging spectrograph on DMSP F16[C]. SPIE, 2002, 4485: 328337.
  • 9Beutler H G.The theory of the concave grating[].Journal of the Optical Society of America.1945
  • 10DIDIER R,ROBERT L.Stratospheric and upper tropospheric aerosol retrieval from li mb scatter signals[].Proceedings of SPIE the International Society for Optical Engineering.2007

共引文献33

同被引文献107

  • 1尼启良,卜绍芳,刘世界,何玲平,张宏吉.微通道板光子计数成像探测器预处理实验研究[J].光子学报,2012,41(6):658-663. 被引量:9
  • 2刘晓红,王咏梅,王永松.高速远紫外光子计数成像读出电路设计[J].空间科学学报,2015,35(1):110-115. 被引量:1
  • 3赵岩,翟百臣,王建立,陈涛.激光距离选通成像同步控制系统的设计与实现[J].红外与激光工程,2005,34(5):526-529. 被引量:10
  • 4XILINX Spartan-3E FPGA Family: Complete Data Sheet[EB/OL]. www.xilinx.com.
  • 5George C Valley. Photonic analog-to-digital converters[J]. Optics Express, 2007, 15(5): 1955-1982.
  • 6A O J Wiberg, Z Tong, L Liu, et al.. Demonstration of 40 GHz analog-to-digital conversion using copy-and-sample-all parametric processing[C]. OFC, 2012: OW3C.2.
  • 7A Khilo, S J Spector, M E Grein, et al.. Photonic ADC: overcoming the bottleneck of electronic jitter[J]. Opt Express, 2012, 20(4): 4454-4469.
  • 8F Coppinger, A S Bhushan, B Jalali. Photonic time stretch and its application to analog-to-digital conversion[J]. IEEE Transactions on Microwave Theory and Technique, 1999, 47(4): 1309-1314.
  • 9Yah Han, Bahrain Jalali. Photonic time-stretched analog-to-digital converter: fundamental concepts and practical considerations [J]. Journal of Lightwave Technology, 2003, 21 (12): 3085-3103.
  • 10Jason Chou, Ozdal Boyraz, Daniel Solli, et al.. Femtosecond real-time single-shot digitizer[J]. Applied Physics Letters, 2007, 91 (16): 161105.

引证文献13

二级引证文献24

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部