摘要
结合神华准能矸电一期2×150MWCFB机组多年的运行实践,针对降低机组供电煤耗方面所采取的措施,从管理、运行、检修、技术改造等多角度进行了综合分析总结。找出了造成供电煤耗高的各方面原因,并提出建议和解决方法,为CFB机组进一步节约燃煤,提高机组热经济性,降低供电煤耗提供借鉴和操作指导。
In order to reduce net coal consumption rate, this paper comprehensively analyzes ways on management, operation, mainte nance, and technical transformation combined with operation practice of 2*150MWCFB unit over the years in Shenhua Zhungeer Gan dian Yiqi,. It finds reasons causing the high coal consumption, and then puts forward some suggestions and solutions, which provide reference and guidance for CFB unit to save coal further that improved the thermal economy of the unit and reduced net coal con sumption rate.
出处
《神华科技》
2013年第6期54-57,共4页
Shenhua Science and Technology
关键词
CFB锅炉
供电煤耗分析
CFB Boiler
Net Coal Consumption Rate
Analysis