摘要 Objective:Metaphyseal-diaphyseal fractures of the distal radius are a major treatment dilemma and orthopaedic surgeons have to pay due consideration to restoration of anatomy of distal radius together with rotation of the radial shaft and maintenance of radial bow and interosseous space.We performed this study to evaluate the clinic-radiological outcome of metaphyseal-diaphyseal fractures of the distal radius treated with long volar locking plates.Methods:This prospective study involved 27 patients (22 males and 5 females) with metaphyseal-diaphyseal fracture of the distal radius.Their mean age was (30.12±11.48) years (range 19-52 years) and the follow-up was 26.8 months (range 22-34 months).All patients underwent open reduction and internal fixation with a long volar locking plate.According to AO/OTA classification,there were 7 type A3,13 type C2 and 7 type C3 fractures.Subjective assessment was done based on the disabilities of the arm,shoulder and hand (DASH) questionnaire.Functional evaluation was done by measuring grip strength and range of motion around the wrist and the radiological determinants included radial angle,radial length,volar angle and ulnar variance.The final assessment was done according to Gartland and Werley scoring system.Results:Postoperative radiological parameters were well maintained throughout the trial,and there was significant improvement in the functional parameters from 6 weeks to final follow-up.The average DASH scores improved from 37.5 at 6 weeks to 4.2 at final follow-up.Final assessment using Gartland and Werley scoring system revealed 66.67%(n=l8) excellent and 33.33% (n=9) good results.There was one case of superficial infection which responded to antibiotics and another carpel tunnel syndrome which was managed conservatively.Conclusion:Volar locking plate fixation for metaphyseal-diaphyseal fractures of distal radius is associated with excellent to good functional outcome,early rehabilitation and minimal complications.
出处 《Chinese Journal of Traumatology》 CAS CSCD 2013年第6期339-343,共5页 中华创伤杂志(英文版)
关键词 Radius fractures Fracture fixation internal Bone plates 桡骨 骨折 锁定 长板 功能评估 固定治疗 端元 平均年龄
  • 相关文献

参考文献16

  • 1Colles A. On the fracture of the carpal extremity of the radius. Edinb Med Surg J. 1814;10:181. Clin Orthop Relat Res 2006;445:5-7.
  • 2Wong KK, Chan KW, Kwok TK, et al. Volar fixation of dorsally displaced distal radial fracture using locking compression plate. J Orthop Surg (Hong Kong) 2005; 13 (2): 153-7.
  • 3Rozental TD, Blazar PE. Functional outcome and compli- cation after volar plating for dorsally displaced unstable fractures of the distal radius. J Hand Surg Am 2006;31 (3):359-65.
  • 4Chung KC, Watt AJ, Kotsis SV, et al. Treatment of un- stable distal radial fractures with the volar locking plating system. J Bone Joint Surg Am 2006;88(12):2687-94.
  • 5Rueh DS, Ginn TA, Yang CC, et al. Use of a distraction plate for distal radial fractures with metaphyseal and diaphyseal comminution. J Bone Joint Surg Am 2005;87(5):945-54.
  • 6Lee SK, Seo DW, Kim KJ, et al. Volar long locking compres- sion plate fixation for distal radius fractures with metaphyseal and diaphyseal extension. Eur J Orthop Surg Traumatol 2013;23(4): 407-15.
  • 7Rampoldi M, Palombi D, Tagliente D. Distal radius frac- tures with diaphyseal involvement: fixation with fixed angle volar plate. J Orthop Traumatol 2011;12(3):137-43.
  • 8Hudak PL, Amadio PC, Bombardier C. Development of an upper extremity outcome measure: the DASH (disabilities of the arm, shoulder and hand). The Upper Extremity Collaborative Group (UECG). Am J Ind Med 1996;29(6):602-8.
  • 9Trumble TE, Schmitt SR, Veddar NB. Factors affecting functional outcome of displaced intra-articular distal radius fractures. J Hand Surg Am 1994; 19(2):325-40.
  • 10Arora R, Lutz M, Hennerbichler A, et al. Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate. J Orthop Trauma 2007;21 (5):316-22.